7 | Manual operation
HYDAC FILTER SYSTEMS GMBH
66 / 124
BeWa MFU-10P 4391553b en-us
7.3.1 Recirculation with filtration/dewatering
For the operating mode recirculation with filtration orrecircula-
tion with filtration/dewatering use the respective filter element
(900)
with the required filtration rating. An overview of the
available filter elements with their filtration rating
(900)
can be
Finding spare parts/accessories [
Fig. 23:
Filter element
Fig. 24:
Example of application: Recirculation with filtration/dewatering
ü
Select the right filter element for an operating mode and
exchange this according to Chapter
1.
Connect the suction hose to the oil tank/container and fit
the suction hose in it and also secure it against falling
out.
2.
Connect the pressure hose to the oil tank/container and
fit the pressure hose in it and also secure it against fall-
ing out.
3.
Connect the filter unit to the voltage source.
4.
Switch the filter unit on at the main switch.
1
2
3
4
5
6
7
8
9
10
A