FAM 15/30 ATEX
Error messages / troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 49 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
[H10] Change fluid filter
Step
DESCRIPTION
Malfunction:
"Replace fluid filter"
1.
Press RESET key
2.
Switch off the FAM at the main switch
3.
Close ball faucets on the IN and OUT connections
4.
Empty filter housing via the drain ball valve
5.
Open filter housing, remove filter elements from housing
6.
Insert new filter elements, close filter housing
7.
Open ball faucets on the IN and OUT connections
8.
Switch the FAM on with the main switch
9
Malfunction reappears after ~ 4 minutes?
->a. Yes
-> proceed to Step 11.
10.
->b. No
-> proceed to Step 12.
11.
Check differential pressure switch and supply lines
12.
The failure is repaired.