7 | Performing Maintenance
HYDAC FILTER SYSTEMS GMBH
44 / 60
MoWa CMP43x0-5 4191543c en-us print
7.1 Maintenance table
Daily
Monthly
Annually
As required Additional information
1
Visual check of
electric
equipment
1
Cleaning/
Changing the
protective screen
2
Cleaning/
Changing the
protective screen
2
1 - Operating personnel; 2 - Specialist personnel – Mechanical
7.2 Visual check for leaks
With a visual check, check the hydraulic connections and
components for leaks.
If there are leaks, switch off the unit / system immediately and
eliminate the leaks immediately.
7.3 Visual check of electric equipment
Check the electrical components (cables, cable glands,
switches, sensors, etc.) visually for damage. Allow the
damaged parts to be replaced immediately.
7.4 Cleaning/Changing the protective screen
A protective screen is fitted upstream the pump on the suction
side to protect the pump from coarse contaminant particles.
1
2
3
4
5
6
7
8
A
Summary of Contents for CMP 43x0-5 Series
Page 60: ...www hydac com ...