7.1
SECTION 7 - OPTIONS
MIST COOLANT OPTION
Mist Coolant – the air powered pump delivers a regulated number of pulses of lubricant to a single applicator nozzle.
The unit has two control screws.
Pulse / Minute – adjusts rate of lubricant use. About 8 to 12 pulses per minute is optimum – more is not better.
Air Screw – regulates the jet of air that projects the lubricant from the nozzle onto the blade. Adjustment should be such
that lubricant covers the blade without blowing the mist beyond the back edge of the blade.
Note: A new blade may require initial lubrication with a small quantity of mist coolant applied to the blade to prevent
squealing.
PULSE / MINUTE
AIR SCREW
FOR OPTIONAL DRAWINGS AND PARTS LIST SEE PDF
ON ATTACHED CD
VARIABLE VISE PRESSURE OPTION
Vise clamping pressure adjustment is located on the top of the control console. Clamping pressure is indicated by the
pressure gauge adjacent to pressure control knob. Turning knob clockwise increases clamping pressure. The clamping
pressure can be changed infinitely from 50PSI to 1000PSI (full pump pressure). It has to be taken under consideration
that clamp pressure setting will affect the clamp speed. The actual usable low clamp pressure setting maybe higher than
achievable by controls and is limited by mechanical friction of the vise assemblies.
Summary of Contents for V-25APC
Page 2: ......
Page 13: ...0 9 ...
Page 16: ...0 12 ...
Page 59: ...4 1 ELECTRICAL SCHEMATICS SEE PDF ON ATTACHED CD SECTION 4 ELECTRICAL ...
Page 60: ......
Page 64: ......
Page 72: ...8 2 V 25APC 5 BARFEED LAYOUT SHEET 1 ...
Page 73: ...8 3 V 25APC 5 BARFEED LAYOUT SHEET 2 ...
Page 74: ...8 4 V 25APC 10 BARFEED LAYOUT SHEET 1 ...
Page 75: ...8 5 V 25APC 10 BARFEED LAYOUT SHEET 2 ...
Page 76: ...8 6 ...
Page 78: ......