Hycontrol HYVENT Installation And Operation Manual Download Page 1

HYVENT

Email: [email protected]   Web: www.hycontrol.com

Tel: +44 (0)1527 406800   fax. +44 (0)1527 406810

SILO DUST COLLECTOR / FILTER UNIT

INSTALLATION AND OPERATION MANUAL

Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire 

B98 7DP, UK

v1.3 MS0820

Hyvent Manual

Summary of Contents for HYVENT

Page 1: ...b www hycontrol com Tel 44 0 1527 406800 fax 44 0 1527 406810 SILO DUST COLLECTOR FILTER UNIT INSTALLATION AND OPERATION MANUAL Hycontrol Limited Larchwood House Orchard Street Redditch Worcestershire B98 7DP UK v1 3 MS0820 Hyvent Manual ...

Page 2: ...rical supply 3 1 INTRODUCTION 1 Compressed air supply 2 Pressure system regulations 2 Usage 2 Health Safety 2 3 INSTALLATION 3 Installation and assembly 3 Cartridge installation 4 General operating parameters 5 Start up 6 5 ADJUSTMENT OF THE CLEANING CYCLE 6 Interval 6 6 MAINTENANCE AND SERVICE 7 Inspection of compressed gas equipment 7 7 TROUBLESHOOTING 8 9 SPARE PARTS 9 10 CONTROLLER SET UP AND ...

Page 3: ...anges to the process and or the dust being handled should be assessed to ensure that no hazard is introduced and control over the contaminant is not compromised Please contact Hycontrol if in doubt The Hycontrol Hyvent dust collector and filter unit has been designed to form an integral part of Hycontrol s advanced SHIELD and SHIELD Lite silo protection system SPS Please refer to other manuals for...

Page 4: ...g into service This is particularly important when considering if the items have or can generate ignition sources Consideration should be given to all components of a system If the unit is supplied with an explosion panel or flameless venting device the unit should be positioned such that the products of the explosion flame and pressure in the case of a vent panel and pressure in the case of the f...

Page 5: ...anifold is a 1 parallel threaded female fitting Consumption approx 11 7 m hr Operating pressure 5 0 6 0 barg AC units input supply 230 V or 115 VAC Note See appendix for wiring diagram details Please be advised that failure to use the correct supply required can result in damage to the PCB and will invalidate the warranty 3 INSTALLATION Handling All handling and lifting activities should be carrie...

Page 6: ...iance Cartridge installation Any work carried out on the equipment should be carried out by competent persons and in accordance with current legislation When removing and replacing elements the following procedure must be adhered to Please ensure these bolts are refitted after the cowl has been lowered back into position Once the unit is secured in position remove the temporary manifold protection...

Page 7: ...rrectly fitted Ensure access door is sealed We recommend commissioning of the unit is carried out by experienced and competent personnel Commissioning requires adjusting the system airflow to the design duty and taking static pressure readings as a basis point for reference and future thorough examinations and tests DO NOT plug or make connections to the solenoid valve vent ports as this may inhib...

Page 8: ...being handled generalised as Specific Gravity SG and stickiness Note cleaning cycle adjustment requires access to an enclosure containing live terminals Isolate before opening and only return the power when needing to make the adjustments taking extreme care The cleaning cycle has two modes of adjustment Duration and Interval Duration Interval Start up Light sticky dust long duration 5 ADJUSTMENT ...

Page 9: ... the dirty contaminated section of a dust collector Maintenance access If deliveries are infrequent i e less than 1 per week it is recommended that a cleaning cycle is run at least once to operate the filter thereby optimising the life of the filter cartridges and keeping fully functional for when required To ensure trouble free operation and minimise the risk of unscheduled stoppages it is advise...

Page 10: ...blinding change if necessary Check for blocked ducts Please note that for special applications the above data may vary Note the stated duties are normal conveying rates Allowances have been made for the surge experienced at the end of a load when transfer is from a lorry tanker For specific applications and recommendations please contact Hycontrol No responsibility is accepted for any application ...

Page 11: ...activation 5 Press key B to go back to the function menu FO8 Output voltage 24V 115V 230V see HV OFF Cycle stops for cleaning consent missing D6 open P Cycle stops for low dPby external pressure switch C6 Open 0 Cycle stops for fan OFF D1a Open Cycles after fan stops Blinking dots NOTE 1 The device will automatically switch from Set Mode to Run Mode if no key is pressed for 5 minutes A01 Number of...

Page 12: ...play flashing indicates the number of the Pulse Valve with a fault due to overload Alarms Use a jumper for unused inputs if you enable them flashing dots cleaning cycles in progress after fan has switched off if selected see set up F05 B2x SETACTIVATION TIME FOR EACH OUTPUT FROM 0 05 TO 5 00 SEC C6 ON OFF CLEANING CYCLE BYEXTERNALPRESSURE VOLT FREE SWITCH If contact C6 is open the cleaning stops a...

Page 13: ... cycle can start from the first electro valve HV INPUT AND OUTPUT VOLTAGE SELECTION BY JUMPERS JP1 JP2 JP3 ON THE BOARD Use the jumpers on the board to select the supply voltage and the output voltage for the electro valves G1 MAXIMUM LOAD POWER FOR 25W OUTPUT FOR MAX 5 SEC JP2 Output voltage selection between 24 115 230v only with 115vAC or 230vAC power supply JP3 Output voltage selection between...

Page 14: ...www hycontrol com 12 12 TECHNICALDRAWINGS ...

Page 15: ...www hycontrol com 13 Larchwood House Orchard Street B98 7DP United Kingdom Tel 44 0 1527 406800 Redditch Worcestershire www hycontrol com Hycontrol Ltd Email sales hycontrol com HYVENT HYVENT ...

Page 16: ... All rights reserved MATRIX SYSTEM WIRING TO CLEANING CONTROLLER FOR HYVENT FILTERS Tel 44 0 1527 406800 www hycontrol com Redditch Worcestershire Email sales hycontrol com B98 7DP United Kingdom Hycontrol Ltd Larchwood House Orchard Street ...