background image

3

2. Installation

Wall Mounting 

•  

Do not install in areas where there is a risk of water freezing in the heater.

•  

Do not install the heater where the consequences of a leak could be unusually    

severe. (eg above computer equipment)

•  

When choosing a location for the heater, consider the visibility of any leak that 

might arise. This is particularly important when locating in a concealed area such 

as a cupboard.

•  

The heater must be mounted horizontally with the inlet and outlet connections 

at the bottom of the heater (see diagram below).

Flow

HOT

OUTLET

HOT TAP

SERVICE VALVE

COLD MAINS

SUPPLY

L

N

E

PCB

RELAY

THERMAL

CUT OUT

TANK

TRIAC

230mm

380mm

90mm

70mm

IN96T_Layout 1  08/06/2015  16:12  Page 3

Summary of Contents for Aquila IN96T

Page 1: ...Product Instruction Manual Aquila IN96T 9 6kW Instantaneous inline water heater V15 6 4 Version 3 2 Jan 2015...

Page 2: ...in accordance with the latest edition of the IEE wiring regulations Only connect the appliance to a power supply that conforms to the specification stated on the rating plate The appliance must be ea...

Page 3: ...ak could be unusually severe eg above computer equipment When choosing a location for the heater consider the visibility of any leak that might arise This is particularly important when locating in a...

Page 4: ...losses through the pipework Once the preferred location has been decided offer the heater to the wall Ensure the unit is level and mark the hole locations onto the final mounting surface see diagram...

Page 5: ...ately earthed It is recommended a service valve be fitted on the cold feed to facilitate future maintenance Turn on the cold mains feed and draw water through the heater for several minutes by opening...

Page 6: ...ia a double poled switch The heater must be earthed Isolate electric and water supply before electrical installation Refer to the rating label on the heater to ensure correct specification of installa...

Page 7: ...rate at which hot water can delivered Selecting a temperature Turn on the heater using the Power On Off On first installation the temperature setting will default to 380C To adjust this press the up d...

Page 8: ...intain a suitable temperature during cold periods Overheat Protection In the unlikely event of a heater malfunction the unit is fitted with a manual reset thermal cut out This is located under the cov...

Page 9: ...t 42A 42A Min Max temperature setting 30 60 C Over heat protection temperature 75 C 5 Minimum operating flow rate 2 5L Min Minimum operating pressure 0 1MPa Maximum rated pressure 0 75MPa Required Wat...

Page 10: ...setting see section 6 1 No display on Unit in standby Turn On the heater the heater see section 6 1 Power supply problem Check that power is supplied to heater and is correct specification as per the...

Page 11: ...r a period of one year from the date of purchase Hyco will in its sole discretion replace repair or refund any faulty unit Incorrect installation and failure to follow correct operating instructions a...

Page 12: ...king life this equipment must not be disposed of as household waste It must be taken to a local authority waste collection centre or to a dealer providing this service Disposing of electrical and elec...