background image

2A

1. Safety Introductions

 

WARNING

Please keep this User Manual for future consultation. If you sell the fixture to another
user, be sure that they also receive this instruction booklet.

Unpack and check carefully there is no transportation damage before using the fixture.

Before operating, ensure that the voltage and frequency of power supply match the
power requirements of the fixture.

It’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.

Disconnect main power before servicing and maintenance.

Use safety chain when fixes this fixture. Don’t handle the fixture by taking its head only,
but always by taking its base.

Maximum ambient temperature is Ta : 40

. Don’t operate it where the temperature is

higher than this.

In the event of serious operating problem, stop using the fixture immediately. Never try
to repair the fixture by yourself. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical assistance
center. Always use the same type spare parts.

Do not connect the device to any dimmer pack.

Do not touch any wire during operation and there might be a hazard of electric shock.

To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain
or moisture.

The housing must be replaced if they are visibly damaged.

Do not look directly at the LED light beam while the fixture is on.

Warning

To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.

Do not open the unit within five minutes after switching off.

The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged.

Please read the instructions carefully which includes important

information about the installation, operation and maintenance.

Summary of Contents for HSF 5.4

Page 1: ...User Manual Please read the instructions carefully before use ...

Page 2: ... OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 Installation 4 How to set the unit 5 How to control the fixture 6 DMX512 Configuration 7 DMX512 Connections 8 Trouble shooting 9 Fixture Cleaning ...

Page 3: ...using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Do not connect the device to any dimmer pack Do not touch any wire during operation and there might be a hazard of electric shock To prevent or reduc...

Page 4: ...e operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by ...

Page 5: ...turn to the original mode 4 2 Main Function Chart 5 How to control the fixture 1 Black Out Turn on off 2 Auto Auto show 3 Sound Sound active 4 Strobe Only JUMP and Static color mode The corresponding button is 0 9 this button has effectivity 5 Fade JUMP Gradual change mode Jump change mode switch 6 Sensitivity sound sensitivity adjust 7 R Red dimmer in the dimming mode 8 G Green dimmer in the dimm...

Page 6: ... G B W A UV Gradual change speed adjust jump change speed adjust 16 0 Function switch Dimming mode and monochromatic mode 6 DMX512 Configuration 6 channels Mode Channel Value Function CH1 0 255 RED dimmer CH2 0 255 GREEN dimmer CH3 0 255 BLUE dimmer CH4 0 255 WHITE dimmer CH5 0 255 Amber Yellow dimmer CH6 0 255 Purple UV dimmer 10 channels Mode Channel Value Function CH1 0 255 Master dimmer CH2 0 ...

Page 7: ...annot be branched or split to a Y cable Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 oh...

Page 8: ...to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C Some fixtures don t respond to the easy cont...

Page 9: ...r particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days ...

Reviews: