40
I
nstallatIon
General information
Installation of your HWAM woodburning stove must always comply with local building regulations. It is
a good idea to consult your local chimney sweep before installing, since he will be the one to sweep the
chimney and stove.
Always follow the instructions of the manual carefully and make sure that the installation is carried out
by a qualified professional.
HWAM packaging material should always be handled in accordance with the local rules for waste handling.
Room requirements
There must be a constant supply of fresh air to the room in which the stove is to be installed. A window that
opens or an adjustable air vent should be sufficient, but it is also possible to connect the stove to a HWAM
combustion air system. The air inlet/grating must be placed so that they do not become blocked.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a flammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
Load-bearing capacity of floor
Before installing the stove, you must ensure that the load-bearing capacity of the floor can withstand the weight
of the stove and the chimney. The weight of the chimney should be calculated according to its dimensions and
height.
Technical data
Model
Weight
Height
Width
Depth
HWAM 3110c/3110m
87/84 kg
75.5 cm
47.9 cm
41.4 cm
HWAM 3110c/3110m on a pedestal
101/98 kg
105.5 cm
47.9 cm
41.4 cm
HWAM 3120c/3120m
107 kg
100.5 cm
47.9 cm
41.4 cm
HWAM 3130c/3130m
113/110 kg
125.9 cm
47.9 cm
41.4 cm
Heat storing slabs, HWAM 3130
32 kg
HWAM 3220c/3220m
91/88 kg
109.9 cm
47.5 cm
41.3 cm
The stove is mainly made of sheet iron, with some items made of cast iron.
Test results from nominal test EN 13240
Nominal heating effect
4.5 kW
Smoke temperature
254ºC
Exhaust gas flow
5.1 g/s
Efficiency
78,1%
Distance to inflammable materials
Your HWAM woodburning stove should always be installed on a non-combustible hearth. If it is installed
on a wooden floor or similar, the floor must be covered with a non-combustible material.
If HWAM 3110 is placed on a flammable floor, always mount it on a plinth whether or not the floor is
covered by a non-flammable material, such as a plate of glass or steel. The plinth is an accessory. Contact
your HWAM dealer for more information.
e
nglIsh
Summary of Contents for 3110
Page 2: ...2 ...
Page 4: ...4 B C A D 11 12 14 14 15 3 1 1 4 45 4 3 2 1 9 11 10 17 1 6 5 7 8 2 3 15 4 16 4 3 14 12 13 ...
Page 5: ...5 F 6 2 1 3 4 5 G 3 0 E 1 ...
Page 6: ...6 1 6 6 7 4 5 9 8 2 3 H1 10 10 11 ...
Page 7: ...7 H2 ...
Page 8: ...8 K ...
Page 50: ...50 ...
Page 51: ...51 ...
Page 52: ...52 ...
Page 53: ...53 ...
Page 54: ......
Page 55: ......