Figure 1
Installing The Electric Heat Accessory
Table 1
−
Accessory Heater Usage
Part Number
Description
Use with Model Sizes
EHC09AKCN3
9 kW, single phase, no internal circuit protection
ALL
EHC15AKF3*
15 kW, single phase, with fuses
ALL
EHC15AKB3*†
15 kW, single phase, with circuit breakers
ALL
EHC20AKF3*
20 kW, single phase, with fuses
ALL
EHC20AKB3*†
20 kW, single phase, with circuit breakers
ALL
EHC25AHCF3
24 kW, supplied as 3 phase, field convertible to single phase, with fuses
48
−
60
EHC30AHCF3
30 kW, supplied as 3 phase, field convertible to single phase, with circuit breakers
48
−
60
† EHC15AKB3 & EHC20AKB3 are not approved for use in Canada (must use fused heaters and certified single point wiring kit).
* 15kW & 20kW are not recommended for specific heat pump applications, see AIRFLOW DELIVERY (CFM)
HEAT PUMP MINIMUM CFM WHEN USING ELECTRIC HEAT (CFM)
FCM
Model Size
Outdoor
Unit Size
Heater Size kW
9
15
20
24, 30
24
18
625
−−
−−
−−
24
725
875
−−
−−
30
875
875
1040
−−
36
970
970
1040
−−
36
24
875
−−
−−
−−
30
875
1100
1150
−−
36
975
1100
1225
−−
42
1125
1125
1225
−−
48
30
875
875
1150
−−
36
975
1100
1225
−−
42
1125
1125
1225
−−
48
1305
1305
1305
1400
60
36
1100
1350
1350
−−
42
1125
1350
1350
−−
48
1300
1350
1465
1750
60
1625
1625
1750
1750
A/C MINIMUM CFM WHEN USING ELECTRIC HEAT (CF
M)
FCM
Model Size
Heater Size kW
9
15
20
24, 30
24
Heater Only
625
725
875
−−
36
700
850
1050
−−
48
700
850
1050
1400
60
1050
1050
1050
1750
NOTES:
1. Heater Only
−
Air conditioner with electric heater application.
2. These airflows are minimum acceptable airflows as UL listed. Actual airflow delivered will be per airflow delivery chart for Electric Heating
Modes.