Huvitz CLM-9000 Service Manual Download Page 1

 

Service Manual 

Auto Lensmeter CLM-9000 

 

 

 

 

 

Summary of Contents for CLM-9000

Page 1: ...Service Manual Auto Lensmeter CLM 9000...

Page 2: ...13 2 7 HOW TO SET UV 14 2 8 HOW TO CHANGE THE LED ASSEMBLY 15 2 9 HOW TO CHANGE THE LED ASSEMBLY 15 2 10 HOW TO CHANGE THE PINHOLE HOUSING 16 3 REPAIR STANDARD 17 3 1 REMOVING COVER ASSEMBLY 17 3 2 DI...

Page 3: ...4 3 INSPECTING SMPS 39 4 3 LCD TEST 40 4 4 LED TEST 41 4 5 UV MODULE TEST 42 4 6 PD TEST 43 4 7 THERMAL PRINTER TEST 44 5 HOW TO UPGRADE THE OS PROGRAM 45 5 1 INTRODUCTION 45 5 2 HOW TO UPGRADE THE OS...

Page 4: ...eter CLM 9000 3 1 Introduction 1 1 Components List Figure 1 Components Names I LCD Display Key Button Memory Button Marker Lever Printer Cover Table Lever Lens Table UV Cover Lens Holder Lens Support...

Page 5: ...4 AUTO LENSMETER Figure 2 Components Names II Figure 3 Components Names III Power Switch Power Cable...

Page 6: ...wer ON 1 Examining the Internal Components First 2 Inspecting The value S C A Prism Checking Abnormal State Cleaning the Pinhole Power off and on Checking Abnormal State Setup Again Exit Normal State...

Page 7: ...ed of 2 dimentional CMOS sensor The followings are the components of each part Emitting Light Part Optic LED 545nm Ball Lens condenses the light radiated from Optic LED Rubber Ring fixes ball lens Fil...

Page 8: ...ns with plus diopter parallel light that has transmitted the collimator lens converges through the measuring lens passes the pinhole and then makes image on CMOS On the other hand in case of concave l...

Page 9: ...Then you can hear the beep sound B Press the two buttons together in the third button and sixth button C Check that SETUP mark flickers in the left upper area of the centric circle Setting and Calibra...

Page 10: ...on D It will have 6th DIP 0 00 message If not using INDEX INDEX buttons select 6th E Also if the message doesn t have 0 00 value using D 0 01 D 0 01 buttons adjust it to 0 00 value F Press SAVE G Alig...

Page 11: ...standard lens and move it so that Marking OK will appear C I and U values in red circle should be within 0 03 D Press the LENS SETUP button E Press the MEASU button F Determine the lens to measure by...

Page 12: ...lecting the 2 lens from the standard lens set place it on the lens cap D Using D 0 01 and D 0 01 buttons make lens value to the real value in the standard model eye specification E Rotate the lens to...

Page 13: ...cylindrical lens on the lens cap C Using 0 01 and 0 01 button make lens value to the real value in the standard model eye specification D Find lens center I and D values cannot bigger than 0 03 E Rot...

Page 14: ...PD bar at the most left side And press L Lim button C Place the PD bar at the most right side And press R Lim button D Move PD bar to the left 10mm And press PD Set button E Repeat step D F When PD ba...

Page 15: ...UV cover C Place UV lens on the UV sensor For UV lens 0 place no lens For UV lens 100 cover the UV sensor D Select UV lens kind by using INDEX button E Make real UV lens value by using 0 1 0 1 button...

Page 16: ...r Frame should be replaced The procedures for changing the upper frame Assembly are as follows A Remove the Bottom Cover Side Cover Front Upper Cover and Upper Frame B Place the new Upper Frame and fa...

Page 17: ...ut the screws in Upper Holes D Lift up the Pinhole Housing and replace it the new one E Turn on the machine and go to engineer mode Press LENS SETUP ALIGN F Rotate the Pinhole Housing to make A12 valu...

Page 18: ...Auto Lensmeter CLM 9000 17 3 Repair Standard 3 1 Removing cover assembly P I c t u r e...

Page 19: ...osen screws and detach 12 Loosen screws and separate 8 Loosen screws and separate 3 Loosen screws and separate 10 Loosen screws and separate 1 Loosen screws and separate 4 Loosen screws and separate 2...

Page 20: ...Auto Lensmeter CLM 9000 19 3 2 Disassembling LCD ass y P I c t u r e...

Page 21: ...o Component Removal method 1 LCD Back Cover Loosen screws on 1 Remove 4 Loosen screws on 6 and 7 Loosen screws on 2 and separate from 1 Detach 3 and 5 2 LCD Back Panel 3 LCD 4 LCD Front Cover 5 LCD Fi...

Page 22: ...Auto Lensmeter CLM 9000 21 3 3 Disassembling Printer ass y P I c t u r e 1 2 3 4 5 6...

Page 23: ...Cover Right Next disconnect 6 s flat cable from 2 Then remove four screws that fix 2 and separate it Separate 3 and 4 from 1 and take out the Printer paper and 5 Be careful that there is no scratch a...

Page 24: ...Auto Lensmeter CLM 9000 23 3 4 Removing PD assembly P I c t u r e 1 2 4 5 3...

Page 25: ...x 4 from the 1 Then separate it Loosen screw on 2 remove from PD Rack Gear Shaft Remove four screw that fixing 5 Then separate it Take off 3 Pull 1 forward Carefully remove PD bar assy to not make scr...

Page 26: ...Auto Lensmeter CLM 9000 25 3 5 Removing UV assembly P I c t u r e...

Page 27: ...AUTO LENSMETER No Component Removal method 1 UV Bone Remove from 1 Separate 2 3 Detach 4 5 Assembly is the reverse procedure of disassembly 2 UV Sensor 3 UV LED PCB 4 UV Tefron Upper 5 UV Tefron Lowe...

Page 28: ...Auto Lensmeter CLM 9000 27 3 6 1 Removing Movement Left Subassembly P I c t u r e 1 2 3 5 6 7 8 9 10 4...

Page 29: ...Remove two screws to separate 7 10 s sub assembly Separate 10 then separate 8 9 Pull out 4 from 3 and then separate 5 6 Assembly is the reverse procedure of disassembly 2 F T2 Control Pos Pin 3 Foot M...

Page 30: ...Auto Lensmeter CLM 9000 29 3 6 2 Removing Movement Right Subassembly P I c t u r e 1 2 3 4 5 6 7 8 9 11 10 12 13 14 15...

Page 31: ...to separate the Pen assembly Remove three screws to disassemble 14 15 from 11 Remove six screws to disassemble 1 6 And then separate them This time Be careful to lose 5 Assembly is the reverse procedu...

Page 32: ...Auto Lensmeter CLM 9000 31 3 7 Disassemble LED subassembly P I c t u r e...

Page 33: ...d 1 LED Bone Remove four wrench bolts to separate Lens housing bone Assembly form the back Bone Assembly Unscrew 3 and then separate 4 Loosen 4 screws and remove 2 Assembly is the reverse procedure of...

Page 34: ...Auto Lensmeter CLM 9000 33 3 8 2 Removing CMOS Camera assembly P I c t u r e 1 2 4 3...

Page 35: ...emoval method 1 Back Bone Remove cables connecting 3 and 4 Loosen screws and remove 3 Loosen screws and remove 4 Loosen screws and 2 Assembly is the reverse procedure of disassembly 2 Pin Hole 3 CMOS...

Page 36: ...Auto Lensmeter CLM 9000 35 3 9 Removing SMPS Assembly and Power S W and Fuse Inlet P I c t u r e 1 2 3 4 5 6...

Page 37: ...two screws that fix 2 then separate it from 1 Pull out 3 4 from 1 Remove two PCB Supports from 5 And then separate 5 Finally remove screws that fix 6 And then separate 6 Assembly is the reverse proced...

Page 38: ...nge MAIN BOARD replace FRAM because it stores SETUP DATA In normal mode make the switch SW2 in this position On Off Off Off CN21 Camera CN1 Rom Socket CN17 NC CN6 FPGA Jtag CN12 Key Pad FLASH CN19 SVG...

Page 39: ...38 AUTO LENSMETER 4 2 Electrical block diagram...

Page 40: ...heck2 Check the voltage of DC POWER Cable with DMM It should be AC100 220V REFERENCE ELECTRICAL CONSTRUCTION DIAGRAM Check1 Check BUZZER beeps after 2 seconds when you turn on the power switch MODULE...

Page 41: ...ot displayed Check1 SMPS TEST YES Check1 LCD is bright but there is no character or figure Check2 There are horizontal lines on LCD and screen display is malfunctioned Check if CN5 connector of LCD is...

Page 42: ...ss mark isn t displayed in measurement waiting state YES Check1 Place white paper on FILTER COVER and check if circular green light comes out from it Change LED module NO Check1 Change MAIN BOARD PCB...

Page 43: ...LED comes out from UV measurement part NO Change UV LED PCB ASS Y Check1 Check if UV SENSER in UV measurement part is hidden by obstacles such as FILTER COVER NO Check1 Turn on the power switch and en...

Page 44: ...to Lensmeter CLM 9000 43 4 6 PD TEST PD value is not displayed Check1 Check right left switching when you move LEVER right and left compared to the center of PD NO Change MAIN BOARD Change PD MODULE Y...

Page 45: ...roperly Check1 Open PRINTER COVER and check if HEADER LEVER towards upside Check1 Open PRINTER COVER Check2 Check PRINTER PAPER tray Check3 Fill up PRINTER PAPER if PRINTER PAPER is empty or near empt...

Page 46: ...there is PC with Windows operating system and serial cable connected to the Lensmeter with simple process about 5 to 10 minutes he she can upgrade the performance of his her Lensmeter without sending...

Page 47: ...two files the executable file dnw exe the configuration file dnw ini It is no need to install it in your desktop computer Therefore just copy the files to the specified directory B Execute the DNW app...

Page 48: ...ur machine and your computer with the serial cable F Turn on the unit while pressing the first and the fourth buttons After that you ll see some information at the DNW terminal G Click the Transmit it...

Page 49: ...48 AUTO LENSMETER finally you can see the screen as following I Finally turn off and on the machine...

Reviews: