Operator Manual
Auto Lensmeter CLM-3100P
Huvitz Co., Ltd.
Page 1: ...Operator Manual Operator Manual Operator Manual Operator Manual Auto Lensmeter CLM 3100P Huvitz Co Ltd...
Page 2: ...ESCRIPTIONS 12 6 1 MEASUREMENT SCREEN 12 6 2 PROGRESSIVE MULTI FOCAL LENS SCREEN 16 6 3 UV SCREEN 18 6 4 SETUP SCREEN 19 6 5 PRINTOUT FORMAT 24 7 MEASUREMENTS 25 7 1 NORMAL LENSES 25 7 2 FRAMED LENSES...
Page 3: ...so be measured with this CLM3000 4 CLM3000 provides the wide measurement range from 25D to 25D 5 CLM3000 supports precise measurements guaranteed by 0 01D measurement unit 6 Measuring progressive mult...
Page 4: ...tion to keep it normal state 3 Do not install this instrument where it might be exposed to the direct sunlight or too bright indoor light 4 To get accurate measurements always keep it clean Dust may r...
Page 5: ...ponents List and Functions omponents List and Functions omponents List and Functions 3 1 Main Unit 3 1 Main Unit 3 1 Main Unit 3 1 Main Unit Figure 1 Component Names I Figure 1 Component Names I Figur...
Page 6: ...Connector Power Power Power Power Switch Switch Switch Switch Figure 2 Component Names II Figure 2 Component Names II Figure 2 Component Names II Figure 2 Component Names II Power Power Power Power C...
Page 7: ...ies Accessories Accessories Accessories 1 Printing Paper Printing paper 1 roll 2 Protection Cover Plastic cover for protection against dust 1 3 Soft Cloth for a Lens A cloth for removing dust on a len...
Page 8: ...with the average radius of hard contact lens 6 Soft Lens Pad The Pad for measuring soft lens tweezers lens towel 1 7 Foot Switch Optional The foot switch which replaces MEM button 1 8 User s Manual 1...
Page 9: ...ories printing paper protection cover soft cloth for a lens contact lens support user s manual are in it Step 2 Removing the protection tape Remove the protection tape from the lens holder lens suppor...
Page 10: ...Display Prog Display Figure 5 Switching Screen According T Figure 5 Switching Screen According T Figure 5 Switching Screen According T Figure 5 Switching Screen According To the Button Selection o th...
Page 11: ...RANS To highlight the sign of the cylinder value to checks it PRGA PRGA PRGA PRGA To turn on off temporarily the function of auto detection for the progressive lens UV UV UV UV To Enter the UV Measure...
Page 12: ...Descriptions Screen Layout and Descriptions Screen Layout and Descriptions 6 1 Measurement Screen 6 1 Measurement Screen 6 1 Measurement Screen 6 1 Measurement Screen Figure 6 Screen Layout Figure 6...
Page 13: ...ch concentric circle represents prism 0 5 1 2 3 and 4 4 Lens In Measuring Tells whether current lens is a single or a left right lens 5 Press Button Name of the press button at lower part of the scree...
Page 14: ...ing into the left lens mode automatically 11 Level of Arrangement Shows the degree to which the center of lens in measuring matches with the axis Black circular belt will be shown in case you adjust u...
Page 15: ...eft PD 15 Display Unit Displays the unit of data We support unit 0 25 0 12 0 01 In Basic Display 2 PRGA button temporarily toggles the function of the progressive auto detection Especially the heavy d...
Page 16: ...he height of bar is less than triangular indicator that s the near focus 5 Target for far focus 1 Maximum additive value 1 Maximum additive value 1 Maximum additive value 1 Maximum additive value 2 Ho...
Page 17: ...s marker This cross marker displays the current measuring point while finding the far focus 7 Horizontal indicator for near focus This indicator describes how far the current measuring point is from t...
Page 18: ...asnsmission Graph 2 Transmission Ratio Figure 8 UV Screen Layout Figure 8 UV Screen Layout Figure 8 UV Screen Layout Figure 8 UV Screen Layout 1 Transmission Graph Displays the transmission ratio in a...
Page 19: ...T T T T O O O O R R R R L L L L B B B B E E E E E E E E P P P P S S S S T T T T E E E E P P P P P P P P R R R R I I I I S S S S M M M M C C C C Y Y Y Y L L L L I I I I N N N N D D D D E E E E R R R R...
Page 20: ...his system is ready for measuring the right lens ON S R L turns on auto decision of right or left lens Initially this system is ready for measuring the single lens OFF turns off auto decision of right...
Page 21: ...X value applied ABBE constant LOW XX value applied ABBE constant This can be applied to the high refractive lens NORMAL NORMAL NORMAL NORMAL XX designated value for NORMAL ABBE 50 60 MID MID MID MID X...
Page 22: ...Q NO SEQ NO SEQ NO SEQ NO RESET set the customer No 0 PRINTER PRINTER PRINTER PRINTER On turns on the printing Off turns off the printing AUTO AUTO AUTO AUTO PRINTER PRINTER PRINTER PRINTER On turns o...
Page 23: ...nter Key to confirm Pressing the Enter Key at the EXIT causes escape without saving and pressing the Enter Key at the End yields saving the changes PD PD PD PD ON Default turns on the PD function OFF...
Page 24: ...at 6 5 Printout Format 6 5 Printout Format Printout format is as follows Figure Figure Figure Figure 10 Printout Format of Framed Glass 10 Printout Format of Framed Glass 10 Printout Format of Framed...
Page 25: ...Lens Figure 11 How To Measure a Normal Lens Figure 11 How To Measure a Normal Lens Step 1 Step 1 Step 1 Step 1 Press CLEAR button to initialize the state of measurement SINGLE must appear on the upper...
Page 26: ...ure 12 Order for Focusing Step 4 Step 4 Step 4 Step 4 If the lens has astigmatism power turn the lens so that the astigmatism angle become 180 You don t have to control astigmatism power to 180 if the...
Page 27: ...measured data You will see one of the following figures on the left bottom of the screen according to whether there is no lens on the lens support or there is one without lens with lens Figure 13 Dis...
Page 28: ...d lenses Figure 14 Figure 14 Figure 14 Figure 14 Measurement of Framed Lens Measurement of Framed Lens Measurement of Framed Lens Measurement of Framed Lens Step 1 Step 1 Step 1 Step 1 Press S R butto...
Page 29: ...R the selection of the S R button will be ignored You should use S R button to select the lens for measuring in the following three cases when PD function option is not supported PD function is off or...
Page 30: ...PD sensor is meaningless So It is necessary to locate the PD sensor at the origin position before turning on the power In case that Auto R L function is on and PD function is off after the right lens...
Page 31: ...of progressive powered lens The Uncut Lens The Uncut Lens The Uncut Lens The Uncut Lens Eye point mark for distance far Eye point mark for near Lens Table R R R R Figure 15 The structure of single len...
Page 32: ...he framed lens The dimension of progressive powered lens depends on the specification of manufacture The old type progressive lens may not observe the 2 3mm shift toward the frame center Do not lift u...
Page 33: ...automatic Figure 17 The progressive area for the automatic Figure 17 The progressive area for the automatic Figure 17 The progressive area for the automatic detection detection detection detection St...
Page 34: ...er reaches to the upper frame Step 2 Step 2 Step 2 Step 2 Adjust the lens left right horizontal or forward backward vertical in order to place the cross marker at the center of target for far focus St...
Page 35: ...wer frame In case the framed lens pull the lens using the lens table in order to maintain the horizontal position Make sure the horizontal indicator for near focus is located within the range of toler...
Page 36: ...ure 19 The small framed lens Figure 19 The small framed lens Figure 19 The small framed lens Do no lift up the lens by hand at the time of measurement Place the lens holder over the lens in order to h...
Page 37: ...rea is expanded into the far vision focus Solution Place the cross marker at the close point to the center and press MEM button to set the focus of far vision Cause 2 The far focus is close to the upp...
Page 38: ...ens forward backward or left right for measurement 6 Difficult to maintain the horizontal position in case of near vision measurement Cause 1 Wrong measurement of far vision focus Solution Retry the m...
Page 39: ...r the measurement mode for the second ADD value Step 5 Step 5 Step 5 Step 5 Press the MEM button after placing the lens over the third focus The second ADD value will be memorized 7 4 2 Measuring at T...
Page 40: ...40 isn t done or you want a manual decision please press the MEM button...
Page 41: ...ght left and back forth to focus Step 5 Step 5 Step 5 Step 5 Press the MEM button to store the measured data and press the PRINT button to print them 7 6 Soft Contact Lenses 7 6 Soft Contact Lenses 7...
Page 42: ...ow To Measure Transmission Ratio of UV Light Step 1 Step 1 Step 1 Step 1 Enter the UV Measurement Screen to press the MODE and the UV button continuously Step 2 Step 2 Step 2 Step 2 Pull and extract t...
Page 43: ...d then mark focus and cylindrical axis Figure 21 How To Mark Focus and Cylindrical Axis Figure 21 How To Mark Focus and Cylindrical Axis Figure 21 How To Mark Focus and Cylindrical Axis Figure 21 How...
Page 44: ...us and cylindrical axis by using the marking lever 8 Maintenance 8 Maintenance 8 Maintenance 8 Maintenance 8 1 Replacing Printing Paper 8 1 Replacing Printing Paper 8 1 Replacing Printing Paper 8 1 Re...
Page 45: ...F CENTE OFF CENTE OFF CENTE OFF CENTER R R R When the optical center of lens is off too much When the optical center of lens is off too much When the optical center of lens is off too much When the op...
Page 46: ...D Cylinder Axis 0 o 180 o degrees 1 o Step Add Power 0 to 10D Prism Power 0 to 10 270 o 0 to 4 Precision Diopter Steps 0 01 0 125 0 25D Prism Power 0 01 0 125 0 25 Measurement Modes Cylinder Prism Rec...
Page 47: ...00 57600 115200 Dimensions 230 x 245 x 426 mm 9 05 in x 9 64 in x 16 77 in Weight 5Kg Power Supply AC 100 240 V 50 60Hz Options Options Options Options Internal Printer Pupilary Dist UV Lignt UV CLM 3...