-13-
6.3 Grounding
The grounding is carried out by connecting the yellow/green terminal of the supply cable to the grounding
terminal of the power source. Be sure the ground the machine in any situation before connecting the machine
to the power source.
Warning
Do not disconnect the grounding terminal before disconnecting from the power source.
7. Mounting the polishing brushes
Check that the machine is "Off" and disconnect from the power source. Put the polishing brush on the shaft
(see Fig. 4).Check if it is firmly installed. Clamp the machine tightly on to a work bench or a stand. This will
increase safety.
8. Universal work stand
A work stand is additionally available. Refer to Figure 6 for the construction and assembly of the stand.
No. Description
Qty.
1
Stand leg (front/rear)
2
2
Stand leg (left/right)
2
3 Stand
top
1
4 Screw
5
/
16
-18NC x
5
/
8
" 4
5 Hex.
bolt
5
/
16
-18NC x ¾" 16
6 Hex.
bolt
5
/
16
-18NC x 1½" 2
7
Washer
5
/
16
x
23
/
32
°
x
1
/
16
"
24
8 Spring
washer
5
/
16
" 22
9 Hex.
nut
5
/
16
"-18NC 22
9. Electrical components
See Figure 5 for the wiring diagram
Designation Description Specification Remark
KA
Magnetic contactor
240 Vac, 6.0 A
XP
Plug for supply
250 V, 16 A
Cable
H05-VVF, 3 x 0.75 mm²
VDE0620
10. Parts lists
See Figure 7
No. Description
No. Description
1 Screw
28 Rubber
plate
2 Spring
washer
29 Screw
3 Left
support
30 Screw
4
Ball bearing
31
Cover plate
5
Centrifugal switch
32
Dustproof cover
6 Screw
33 Screw
7 Stator
housing
34 Switch
8 Stator
35 Cover
plate