D5R Data Sheet 

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact  

D5R

Dairy & Delicatessen

Electrical Data

Number of Fans 

8 ft

12 ft

Refrigeration – 9W 

4

6

Export – 9W 

4

6

Amperes

Watts

Merchandiser

8 ft

12 ft

8 ft

12 ft

Fans (Refrigeration)

Standard (120V 60Hz)

2.80

4.20

210

320

Energy Efficient (120V 60Hz)

1.52

2.28

100

150

Export (230V 50Hz)

1.52

2.28

228

342

Constant On Anti-sweat Heaters

NA

NA

NA

NA

Cycling Anti-sweat Heaters

NA

NA

NA

NA

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz)

3.00

4.40

With Energy Efficient Fans (120V 60Hz)

1.72

2.48

With Export Fans (230V 50Hz) 

1.72

2.48

Maximum Over Current Protection 120V

20

20

Export (230V 50Hz)

15

15

Electric Defrost Heaters (208V 1

Φ

Φ

)

NA

NA

NA

NA

Gas Defrost Heaters (208V)

NA

NA

NA

NA

Standard Lighting

8 ft

12 ft

8 ft

12 ft

1 Row Canopy

0.51

0.77

59

85

Optional Lighting

1 Row Canopy and 1 Row Rail

1.02

1.54

118

170

2 Rows Canopy 

1.02

1.54

118

170 

2 Rows Canopy and 1 Row Rail

1.53

2.31

177

255

3 Rows Canopy

1.53

2.31

177

255

3 Rows Canopy and 1 Row Rail

2.04

3.08

236

340

Optional Shelf Lighting

4 Rows of Shelves

1.84

2.76

224

336

NOTE: 8 foot merchandiser has two columns of four rows of lighted shelves and 

12 foot merchandiser has three columns of four rows of lighted shelves.

Summary of Contents for IMPACT D5R

Page 1: ...AND THERMOSTATS A 9W Fan Assembly 1 0047000 Fan Motor Evaporator 0435961 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrig...

Page 2: ...rnal support and center support 40 5 8 1032 40 5 8 1032 Distance between edges of center supports NA 44 1118 Stub up area between front skid rail and splashguard 7 178 7 178 Electrical Service Electri...

Page 3: ...T UNLIT SHELVES Parallel 1560 1500 Conventional 1660 1595 HUSSMANN PEG SHELVES DELI ONLY Parallel 1680 1620 Conventional 1780 1715 For all refrigeration equipment other than Hussmann use conventional...

Page 4: ...gy Efficient Fans 120V 60Hz 1 72 2 48 With Export Fans 230V 50Hz 1 72 2 48 Maximum Over Current Protection 120V 20 20 Export 230V 50Hz 15 15 Electric Defrost Heaters 208V 1 NA NA NA NA Gas Defrost Hea...

Page 5: ...hted Shelves Note 8 Foot merchandiser has two columns of four shelves and 12 Foot merchandiser has three columns of four shelves Shelf Harness Shelf Light Circuits BL G R 5 Connector BL G R 5 Connecto...

Page 6: ...models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TA...

Page 7: ...ors Fully Closed Double walled telescoping doors slide both left and right NOTE Consult Cooler Close off Kit for instructions on connecting the merchandiser to the cooler Rear View of 8 Foot Dairy Mer...

Page 8: ...the cooler Rear View of 12 Foot Dairy Merchandiser 23 3 4 130 1 4 37 3 4 67 1 2 79 1 2 23 3 4 D o o r s F u l l y O p e n e d D o o r s F u l l y C l o s e d Double walled telescoping doors slide bot...

Reviews: