background image

Rev.0309

11

PLEXIGLASS & ACRYLIC CARE

CLEANING

Clean with plenty of nonabrasive soap (or detergent) and
luke warm water, using the bare hand to feel and dislodge
any caked-on dirt. A soft, grit-free cloth, sponge or cham-
ois may be used, but only as a means of carrying the water
to the plastic. Dry with a clean damp chamois or clean
soft cloth such as cotton flannel. Hard, rough cloths or
paper towels will scratch the acrylic and should not be
used.

WAXING

If after removing dirt and grease, the acrylic can be waxed
with a good grade commercial wax. This will improve the
appearance of the surface by filling in most minor scratches.
Wax should be applied in a thin even coat and brought to
a high polish by rubbing lightly with a dry clean soft cloth,
such as a cotton flannel. Excessive rubbing may cause
scratching and/or buildup an electrostatic charge which
attracts dust and dirt to the surface. Blotting with a clean
damp cloth is recommended to remove charge.

ANTISTATIC COATINGS

For acrylic used indoors, antistatic coatings successfully
prevent the accumulation of an electrostatic charge for
periods of several months—if the surface is not washed
or wiped down with a wet cloth. Between applications of
the antistatic coatings, the parts need only be dusted with
a soft clean cloth to maintain a good appearance. In use,
liquid antistatic coatings should be applied in a very thin
even coat. If beads appear as it is applied, the coat is too
thick and the excess should be removed with another cloth.
Allow the coating to dry, then bring to a high gloss with a
soft cloth.

ELECTRICAL PRECAUTIONS

BEFORE SERVICING – Always disconnect

electrical power at the main disconnect when

servicing or replacing any electrical component

This includes (but not limited to) Fans, Heaters,

Thermostats, and Lights.

REPLACING FLUORESCENT LAMPS

Fluorescent lamps are furnished with moisture resistant
lamp holders, shields and end caps. Whenever a florescent
lamp is replaced, be certain to reinstall the lamp shield
and end caps over the lamp. The lamps supplied are single
slim-line or bi-pin type with or without starters.

EVAPORATOR FANS

The evaporator fans are located at the center front of
these merchandisers directly beneath the display pans.
Should fans or blades need servicing, always replace fan blades
with the raised embossed side of the blade TOWARD THE
MOTOR.

COPPER COILS

The copper coils used in Hussmann merchandisers may
be repaired in the field. Materials are available from local
refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.

TIPS & TROUBLESHOOTING

Before calling for service, check the following:

1. Check electrical power supply to the equipment for

connection.

2. Check fixture loading. Overstocking case will affect

its proper operation.

3. If frost is collecting on fixture and/or product, check

that Humidity Control is working properly, and that
no outside doors or windows are open—allowing
moisture to enter store.

FOR PROMPT SERVICE

When contacting the factory,

be sure to have the Case Model and Serial

Number handy. This information is on a plate

located on the case itself.

Maintenance

Summary of Contents for Chino RED

Page 1: ...Chino RED Refrigerated End Display Rev 0309 Installation Operation Manual RED Refrigerated End Display p n IGUP RED 0309 INSTALLATION OPERATION GUIDE...

Page 2: ...required claim forms SHORTAGES Check your shipment for any possible shortages of mate rial If a shortage should exist and is found to be the re sponsibility of Hussmann Chino notify Hussmann Chino If...

Page 3: ...3 Cut PlanViews 23 1 8 12 14 18 22 1 2 6 1 2 58 1 2 40 1 8 14 1 4 RED Refrigerated Self Sevice End Display Scale 1 2 33 1 2 39 Elec Ref Drain 1 33 1 2 72 Variable RED Plan View Scale 1 4 1 39 17 5 9 1...

Page 4: ...correctly will solve most hinge operation problems NOTE A To avoid removing concrete flooring begin lineup leveling from the highest point of the store floor B When wedges are involved in a lineup se...

Page 5: ...rred minimum PVC pipe when used must be supported to main tain the 1 8 pitch and to prevent warping 4 Avoid long runs of condensate drains Long runs make it impossible to provide the fall necessary fo...

Page 6: ...access panel s ELECTRONIC EXPANSION VALVE OPTIONAL A wide variety of electronic expansion valves and case controllers can be utilized Please refer to EEV and con troller manufacturers information shee...

Page 7: ...ponent amperes are listed in the Case Specs section but always check the serial plate BALLAST LOCATION Ballasts are located within the access panel that runs the length of the rear of the case T STAT...

Page 8: ...ghts Levels 4 1 700 6 800 20 34 28 300 28 Forced 8 x 30 1 20 4 0 33 0 60 3 6 4 Air 6 1 700 10 200 20 34 28 300 28 Forced 8 x 30 2 20 4 0 66 1 20 3 6 4 Air 8 1 700 13 600 20 34 28 300 28 Forced 8 x 30...

Page 9: ...PAGE OF 1 1 06 08 01 H WIRESCHEMATICS NEWWIRE RED CASES W2150001 4 CASE 58 HEIGHT REMOTE LIGHT SWITCH 125 01 0307 BUNDLE COLOR ORANGE BALLAST 125 01 3266 FULHAM LH3 120 L BUNDLE COLOR BROWN BUNDLE COL...

Page 10: ...case Do not use EPR valves Liquid Line Solenoids or electronic control devices of any kind as these allow tempera ture swings causing dehydration and excessive energy consumption CASE CLEANING Long li...

Page 11: ...excess should be removed with another cloth Allow the coating to dry then bring to a high gloss with a soft cloth ELECTRICAL PRECAUTIONS BEFORE SERVICING Always disconnect electrical power at the mai...

Page 12: ...mendations b Observation of outside influences such as drafts radiant heating from the ceiling and from lamps Such influence should be properly corrected or compensated for c At the same time checks s...

Page 13: ...gerator charged with the proper refrigerant and lubricant Does the system use the recommended compressor APPENDIX D Recommendations to user 1 0 Hussmann should provide instructions and recommendations...

Page 14: ...IGUP RED 0309 14...

Page 15: ...period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor compressor assembly is available but must be purcha...

Page 16: ...icular unit They can be found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Chino Additional copies of thispublication may be obtained by contactin...

Reviews: