M.47
TE 250 - 310 2012 I.E. / TE 250 - 310 2012 I.E. USA
TC 250 2012 - TC 250 2012 I.E. USA
TXC 250 - 310 2012 I.E. USA
H00924
8
ELECTRICAL SYSTEM
Workshop Manual Ed. 12-2011
• Position of control unit (5) and voltage regulator (6)
(TE – TXC)
Electronic control unit installed with the flat side down.
Voltage regulator installed over the electronic control unit.
Coat voltage regulator with heat grease.
• Securing the starter motor/solenoid starter cable (TE-TXC)
Connect the starter motor/solenoid starter cable (7) as shown in the figure.
• Securing the engine ground to chassis and engine ground to battery
cables (8) (TE-TXC)
The engine ground to chassis and engine ground to battery cables are secured
to the timing chain tensioner screw.
• Battery negative cable routing (TE-TXC)
Routing of engine ground to battery negative cable (8).