ELECTRICAL SYSTEM 14
107
Guideline
The charging current, charging voltage, and charg-
ing duration must not be exceeded.
Maximum charging volt-
age
14.4 V
Maximum charging cur-
rent
3.0 A
Maximum charging time
24 h
Recharge the 12 V bat-
tery regularly when the
motorcycle is not being
used
6 months
(EU) battery charger (26529974000)
Alternative 1
(US) battery charger (26529974500)
These battery chargers test whether the 12 V bat-
tery retains its voltage. It is also impossible to over-
charge the 12 V battery with these battery chargers.
The charging time may be longer at low temperatures.
These battery chargers are only suitable for lithium
iron phosphate batteries. Read the accompanying
instructions for
Husqvarna Motorcycles
accessories.
Info
Never remove cover
1
.
–
Switch off the battery charger after charging and disconnect
from the 12 V battery.
Finishing work
–
Install the 12-V battery.
–
Mount the seat. (
14.4
Changing the main fuse
Warning
Fire hazard
Incorrect fuses overload the electrical system.
–
Only use fuses with the required ampere value.
–
Do not bypass or repair fuses.
Caution
Danger of burns
The voltage regulator gets very hot when the vehicle is driven.
–
Allow the voltage regulator to cool down before performing any work.
Info
The main fuse protects all electrical power consumers of the vehicle. It is located in the starter relay
housing under the seat.
Preparatory work
–
Remove the seat. (
–
Remove the right side panel. (