There are 4 different types of messages:
• Information messages help and give hints on how to
operate the product. An information message is
shown as an information symbol in the bottom bar.
• Caution messages show that something is not
correct. A caution message is shown as a yellow
triangle in the bottom bar.
• Warning messages show faults or safety defects that
can cause mechanical damage. The product will
stop in a short time. The warning is first shown in full
screen with a red warning triangle and text. After you
accepted (C) the warning message, the warning is
shown as a red triangle symbol in the bottom bar (A).
REPLACE WITH CHARGED BATTERY SOON
BATTERY
LOW
C
D
E
F
• Error messages show when the product is stopped
because of a fault or safety defect. The error
message is shown in red with a white triangle and
white text. When the fault is corrected you must
restart the product, turn the OFF/ON/START switch
to ON position. Then turn the OFF/ON/START
switch to START position.
If there are more than 1 active message, the newest
message is added from the right. Push the buttons
adjacent to the arrows (D and E) to move between the
messages in the display.
You can also find a fault list in the "Active faults" in
"Machine status" in the menu button (F). Refer to
"Machine status" menu on page 37
.
Fault codes and descriptions
The fault code numbers for the product are shown on
the display. The fault code numbers for the remote
control (fault code numbers from 1001) are shown on
the information center display.
Fault code number
Message in the dis-
play
Cause
Solution
1
"Softstart error Start
not possible"
General error in soft starter.
Speak to Husqvarna service.
2
"Softstart error Over-
load"
Softstart is overload. The input
voltage is out of range.
Do a check of the input voltage.
Let the product become cool. If
the problem stays, speak to
Husqvarna service.
3
"Wrong incoming
voltage Phase lost"
Incorrect input voltage and phase
loss.
Do a check of the input voltage
and the cables.
5
"Wrong incoming
voltage Grid frequen-
cy"
The grid frequency is out of
range.
Do a check of the voltage source.
6
"Wrong incoming
voltage Voltage too
low"
The input voltage is too low.
Do a check of the input voltage
and the cables.
7
"Wrong incoming
voltage Voltage too
high"
The input voltage is too high.
10
"Grid frequency Out
of range"
The grid frequency does not
agree with the product frequency
setting.
Speak to Husqvarna service.
1401 - 002 - 15.10.2021
95