HUG-500S(E)
Industrial 5 10/100/1000TX
Gigabit Unmanaged Ethernet Switch
User’s Manual
V2.0 6-26-2009
Page 1: ...HUG 500S E Industrial 5 10 100 1000TX Gigabit Unmanaged Ethernet Switch User s Manual V2 0 6 26 2009 ...
Page 2: ...utions HUG 500S E Industrial Gigabit Unmanaged Switch User s Manual Copyright Notice Copyright 2009 Ethernet Direct Corp All rights reserved Reproduction in any form or by any means without Ethernet Direct prior written permission is prohibited ...
Page 3: ... 2 1 2 1 Dimensions and Panel Layout 2 1 2 2 LED Indicators 2 2 2 3 RJ 45 Ports 2 2 2 3 1 RJ 45 Pin Assignments 2 2 2 4 Installing Your Ethernet Direct Switch 2 3 2 4 1 Mounting The Switch 2 3 2 4 2 Wiring The Power Inputs 2 5 2 4 3 Wiring The Fault Alarm Contact 2 6 2 4 4 Cabling 2 6 Appendix A Specifications A 1 Appendix B Troubleshooting B 1 ...
Page 4: ...ork Switching Technology z Complies with IEEE 802 3 IEEE 802 3u IEEE 802 3x IEEE 802 3ab z Provides 5 x 10 100 1000Mbps Ethernet ports with RJ 45 connector z Supports IEEE 802 3x flow control on full duplex back pressure on half duplex z RJ 45 ports support auto MDI MDI X crossover z Provides broadcast storm protection Robust Industrial Design z Robust aluminum case complying to IP 30 housing stan...
Page 5: ...and hardware installation Topics include z Dimensions and Panel Layout z LED Indicators z RJ 45 Ports z Installing Your Ethernet Direct Switch 2 1 Dimensions and Panel Layout Dimensions of HUG 500S E Industrial Gigabit Managed Switch are 30mm W x 95mm D x 140mm H Front Panel Side Panel Unit mm Back Panel Top Panel ...
Page 6: ...S E has 5 10 100 1000Mbps auto sensing ports for 10Base T 100Base TX or 1000Base TX devices connection The UTP ports can auto sense for 10Base T 100Base TX or 1000Base TX connections Auto MDI MDIX function allows HUG 500S E to connect to another switch or workstation without changing straight through or crossover cabling See Cabling section for straight through and crossover cable schematic 2 3 1 ...
Page 7: ...r Inputs Wiring The Fault Alarm Contact and Cabling 2 4 1 Mounting The Switch The are two types of mounting options DIN Rail mounting and wall mounting Users can choose the most suitable mounting installation for your own onsite applications 2 4 1 1 DIN Rail Mounting The DIN Rail mounting kit is attached to the back panel of HUG 500S E by default If not or users want to disassemble the DIN Rail mo...
Page 8: ...steps above 2 4 1 2 Wall Mounting Follow the steps below for wall mounting installation 1 Remove the DIN Rail plate from the switch loosen the screws to remove the DIN Rail plate 2 Place the 2 wall mounting plates on the top and bottom panel of the switch respectively 3 Use the screws to screw the wall mounting plates on the switch 4 Use the hook holes at the corners of the wall mounting plates to...
Page 9: ...f the maximum possible current when wiring connections If the current goes above the maximum ratings the wire could overheat and result in serious damage to your switch 1 Insert the positive and negative wires of your DC supply into the corresponding V and V contacts of the terminal block 2 Tighten the screws to prevent the DC wires from coming detached The acceptable wire range is 12 to 24 AWG ...
Page 10: ... wire range is 12 to 24 AWG 2 4 4 Cabling For RJ 45 port connection prepare twisted paired straight through Category 5 cables for Ethernet connection The linking distance between the switch and the network device must be less than 100 meters 328 ft For 10Mbps connections use 100Ω Category 3 4 or 5 cables For 100Mbps connections use 100Ω Category 5 cables For 1000Mbps connections use 100Ω Category ...
Page 11: ...W x 95mm D x 140mm H Installation DIN Rail mounting Wall mounting Environmental Operating Temp Regular 10 to 70 Extended 40 to 80 Storage Temp 40 to 85 Operating Humidity 5 to 90 RH non condensing Technology Standards IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X IEEE 802 3ab for 1000BaseT X IEEE 802 3x for Flow Control 10BaseT 2 pair UTP STP Cat 3 4 5 5E cables EIA TIA 568 100Ω 100m 100BaseT ...
Page 12: ...1000 6 2 EN61000 6 4 Safety UL cUL CE EN60950 1 Shock IEC60068 2 27 Vibration IEC60068 2 6 Free Fall IEC60068 2 32 Class 1 Divison 2 Pending DNV Pending Environmental WEEE RoHS MTBF 325 000 hrs based on Mil Hdbk 217F GB Warranty 5 years ...
Page 13: ...e above cables for 1000Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnostic LED indicators located on the front panel of the switch can help users to easily monitor the switch IF the power indicator does not light on when the power cord is plugged in you may have a problem with power cord Then check for loose power connections ...