11/WIRING HARNESS, BATTERY
75
–
Check that the power consumer is functioning properly.
–
Close the fuse box cover.
–
Mount the seat. (
14.5
Removing the battery
Warning
Risk of injury
Battery acid and battery gases cause serious chemical burns.
–
Keep batteries out of the reach of children.
–
Wear suitable protective clothing and goggles.
–
Avoid contact with battery acid and battery gases.
–
Keep the battery away from sparks or open fire. Charge only in well-ventilated rooms.
–
In the event of skin contact, rinse with large amounts of water. If battery acid gets in the eyes, rinse with water for at least
15 minutes and contact a physician.
–
Switch off all power consumers and switch off the engine.
–
Remove the seat. (
100422-10
–
Detach fuse box
and swing it to one side.
–
Detach connector
and swing it to one side with connector
.
–
Remove screws
and swing battery cover
with the starter relay to one side.
Swing the EFI control unit to one side.
100423-10
–
Disconnect the negative and positive cables of the battery.
Info
Pay attention to the contact disks between the cable sockets and battery
terminals.
–
Lift battery
up and out.
14.6
Installing the battery
100423-11
–
Insert battery
into the battery tray with the terminals facing to the rear.
Battery (YTZ7S) (
100424-10
–
Connect the positive and negative cables.
Info
Contact disks
must be mounted between battery terminals
and cable
sockets
with the claws facing up.
–
Tighten the screws.
Guideline
Screw, battery terminal
M5
3 Nm (2.2 lbf ft)
Summary of Contents for FE 450 AUS
Page 2: ......
Page 237: ...235...
Page 243: ...WIRING DIAGRAM 241...
Page 247: ...WIRING DIAGRAM 245...
Page 253: ...WIRING DIAGRAM 251...
Page 261: ...WIRING DIAGRAM 259...