Installation
Autobend 6
November, 1999
2-111
Installing Cable to LP Gauges
Follow these steps to install cables to LP gauges:
1.
Remove the gauge lock nut from the harness cord grip for
each cable.
2.
Route cables exiting from the bottom of the AB6 power
cabinet to each gauge.
3.
Re-install and tighten each lock nut for each gauge.
4.
Repeat the following procedures for each gauge assembly:
a.
Connect the two 9-pin connectors at the end of the
gauge cable. They connect to their respective
receptacles at the motor under the gauge housing.
b.
Locate the ground wire (green with yellow stripe).
Attach this wire with the self-tapping screws to the
harness plate.
c.
Pull out any slack in the cable using the cord grip.
d.
Route and secure the cable in a position where it
will not be damaged.