Hunter EZ-DM Installation Manual Download Page 1

ENGLISH

The EZ Decoder System is a unique two-wire output option for 
Hunter ICC2 and HCC controller models only.
•  Do not attempt to use this system with any other model or 

brand of controller.

•  Do not attempt to use EZ-1 decoders with any other decoder 

controller.

EZ Decoders are designed to be easy.  
They do not require special wire.
•  They do require direct burial wire of adequate size for the 

distance of each wire run (see chart). It is even possible to use 
existing wire from “conventional” installations to create a two-
wire path for EZ decoders.

•  The EZ Decoder System does not require waterproof 

connections in order to operate. However, just as in 
conventional systems, waterproof connectors should be used to 
maintain the integrity of the splice and the wire.

Installing the EZ-DM in Hunter ICC2 and HCC Controllers

If the whole system will be two-wire, install the EZ-DM module in 
the first slot in the controller.  
Press the Reset button on the back of the controller face panel for 
the new module to be recognized.
•  Open blue lock lever.
•  Insert module tabs into end of slot, and tip into place.
•  Close locking lever. 
•  Press controller Reset button. Controller will then recognize the 

new module, and the controller  
size will change to 54 stations. 

EZ-DM may also be combined with ICM-800 and ICM-400 
modules for “hybrid” operation. They can use “conventional” 
solenoid wiring and two-wire technology at the same time, up to 
54 stations maximum.
It is recommended to install all conventional modules in the lower-
numbered slots, and install the EZ-DM in the next available slot. 
•  The conventional modules will operate the station numbers that 

are shown on the backplane of the controller, next to the slot.

•  The EZ-DM module can operate remaining station numbers up 

to 54 via the two-wire paths.

•  Do not program duplicate station numbers when combining 

conventional modules and the EZ-DM. If an EZ decoder is 
programmed to station 1, and there is a conventional module in 

the first output slot with station 1, both station “ones” will turn 
on at the same time. This may cause a station error if it causes 
an overloaded current condition.

•  Only program decoder station numbers that are not in use on 

conventional output modules.

EZ-DM Connections

P/MV (Pump/Master Valve): Connects to  
P/MV on power module ONLY if decoder will 
be used for P/MV  

Program button and status LED

Two-Wire path terminals (two paths available)

Decoder Programming Port: Insert decoder red 
and blue wires for programming.

Decoder Programming

•  Each EZ-1 Decoder must be programmed with a station number 

(or as the P/MV) before use. 

•  Insert EZ-1 red and blue wires into ports on the EZ-DM output 

module. It does not matter which color goes in which hole. Use 
the controller face panel (or remote control, if so equipped) to 
start the station number you want to program into the decoder.

•  When the station is shown running in the controller display, 

press the PRG button on the EZDM. When the LED illuminates 
on the decoder, the decoder is programmed with that station’s 
number. Write the station number on the decoder label with a 
permanent marker. It is now ready to install in the two-wire path 
at a valve location.

P/MV (Pump/Master Valve)

To program P/MV output for decoder: With no stations running, 
connect the decoder to the port, and press the PRG button on 
the EZDM. When the decoder LED illuminates, the decoder is 
programmed as the P/MV output.

IMPORTANT:

 Connect a jumper wire from the P/MV terminal 

on the controller power module, to the P/MV terminal on the 
decoder output module, for decoder operation of P/MV. If the P/
MV output will not be used, or if the P/MV is nearby and will be 
wired directly to the controller without a decoder, do not install a 

jumper wire. The P/MV output on the controller power module 
will operate normally if the jumper wire is not connected.

Two-Wire Path Connections and Rules

•  The output of the EZ-DM wire paths is 24VAC, 50/60 Hz. 

Voltage is only present on the paths when stations are active. 

•  The red and blue wire path terminals on the EZ-DM indicate that 

they are connected to the EZ-1 decoder red and blue wires, but 
the wire that extends the two-wire path does not need to be 
color-coded. It does not matter if the decoder “red” connects to 
the terminal “blue.” 

•  There is no polarity on the EZ decoder system. Use direct  

burial-rated irrigation wire. 

•  The size of the wire determines the effective distance of the 

two-wire path. 

•  See the wiring table for distance specifications with various wire 

sizes.

•  Use irrigation-grade wire connectors for all splices. They can be 

of the same type used for solenoid connections.

Learn more.

 

Visit hunterindustries.com

EZ-DM

 

Decoder Output Module

 

Installation Guide for ICC2  
and HCC Controllers