background image

CAUTION! 
1. Read entire instructions before beginning installation.

2. To avoid possible electrical shock, be certain electricity is

shut off at main panel before wiring.

3. All wiring must be in accordance with national and local elec-

trical codes. If you are unfamiliar with wiring, you should use
a qualified electrician.

WARNING!

1. To reduce the risk of fire or electrical shock, do not use a solid

state speed control with this fan. Use Hunter Controls only.

2. To reduce the risk of personal injury, do not bend the blade

brackets when installing the brackets or cleaning the fan. Do
not insert foreign objects in between the rotating fan blades.

Step 1: Pre-installation Instructions 
A. 

Select installation site. Check to see that in normal use no

object can come in contact with the rotating fan blades. The
mounting site should also meet the precautions listed in Step C
below.

B. 

Installation hardware is included for a standard drywall or

plaster ceiling. You will need a 4" x 1-1/2" or 4" x 1/2" outlet box
and wire nuts (2) which can be purchased from any hardware
store or electrical supply house.

C. 

The fan blades must be mounted at least 7' above the floor.

For maximum efficiency, they should not have any obstruction
(walls, posts, etc.) within 24" of the blade tips. See Figure 1 for
mounting distances.

Step 2: Inspection of Fan
A. 

Unpack the fan carefully to avoid any damage to the 

components.

B. 

Check for any shipping damage to the motor and the fan

blades. If more than one fan is being installed, keep the matched
and balanced blades in sets, as they were shipped. Should one of
the blades become damaged during shipment, return all blades in
the set for replacement.

C. 

Check contents to be certain it contains a bag of parts.

Step 3: Installation of Outlet Box and 
Rough—In Wiring

CAUTION: Your Hunter ceiling fan with accessories can weigh
up to 35 lbs. The following precautions must be taken for safety
and to ensure that your fan is securely mounted to the ceiling. Be
certain electricity is “off” at the fuse panel when inspecting or
repairing installation site. All wiring must meet local and
national electrical codes. Do not mount directly to an unsup-
ported ceiling or to an electrical outlet box. Mounting must sup-
port a 35 lb. fan with accessories.

A. 

Secure metallic outlet box 4" x 1-1/2" or 4" x 1/2" deep to 2

x 4 cross brace between two ceiling joists as shown in Figure 2.
The outlet box must be recessed into the ceiling by 1/16 " mini-
mum. Secure the outlet box to the cross brace by drilling (2)
pilot holes no larger than the minor diameter of the wood screws
( 5/64") and use two #8 x 1-1/2" wood screws and washers. Use
the innermost holes for securing the box. Orient the box so the
outermost holes will be used in Step 4B.

CAUTION: Do not use lubricant on screws.

B. 

Bring electrical cable into the outlet box and attach with an

approved connector. Make certain that wiring meets all national
and local electrical codes. Wire leads should extend at least 6"
beyond outlet box for ease in making connections. See Figure 3.

FORM NO. 41201-01  1/95

- 1 -

©1998 HUNTER FAN CO.

INSTALLATION INSTRUCTIONS

FOR HUNTER CEILING FAN TYPE 2

READ AND SAVE THESE INSTRUCTIONS

Figure 1. Wall Clearances

Figure 3. Wiring Outlet Box

6" MIN. 
LEAD LENGTH

2 x 4 BRACE

CEILING
JOIST

OUTLET BOX

CEILING

CONNECTOR

#8 WOOD SCREW &
WASHER (2) REQUIRED

Figure 2. Outlet Box

7

'

MIN.

TO FLOOR

24"

CLEARANCE

TO

OBSTRUCTIONS

8

'

MIN.

CEILING

TO FLOOR

Summary of Contents for CEILING FAN TYPE 2

Page 1: ...ed during shipment return all blades in the set for replacement C Check contents to be certain it contains a bag of parts Step 3 Installation of Outlet Box and Rough In Wiring CAUTION Your Hunter ceiling fan with accessories can weigh up to 35 lbs The following precautions must be taken for safety and to ensure that your fan is securely mounted to the ceiling Be certain electricity is off at the f...

Page 2: ...ceiling plate See Figure 4 B Thread the lead wires through the opening in the ceiling plate and install the ceiling plate to the 2 x 4 brace which sup ports the outlet box Use 2 10 wood screws 3 long and 2 flat washers for mounting Drill 2 pilot holes for mounting screws 9 64 diameter See Figure 4A Step 5 Fan Assembly CAUTION Do not lift motor by wires A Assemble the fan housing to the motor hange...

Page 3: ...an and also as a ball type hanging fan Thus installer s choice Customer should read Steps 6 through 8 and decide which style of mounting to use Step 6 Fan Assembly Low Profile Fan A The canopy has 4 holes in the bottom The large center hole fits over the adaptor on top of the fan The 3 remaining holes are for the canopy assembly screws Place the canopy on top of the fan and align the proper holes ...

Page 4: ...white and green wires on one side of the outlet box and the black and black white wires on the other side of the box The splices should be turned upward and pushed carefully up into the outlet box Step 8 Finish Fan Assembly A The ceiling plate has 3 mounting screw holes located on the side Install 2 10 32 x 1 2 Phillips round head screws halfway into two of these holes See Figure 8 Remove the fan ...

Page 5: ... off and allow to stop Slide reversing switch to the opposite position and switch fan back on See Figure 13 Speed Control As an option a wall mounted speed control switch is available from your Hunter dealer Step 10 Assemble Upper Switch Housing A First feed the upper plug connector through the hole in the top of the upper switch housing Using 3 6 32 x 3 8 long screws with lockwashers supplied in ...

Page 6: ...ration 1 Blade brackets loosely screwed to motor 1 Tighten screws until snug 2 Blade screwed loosely to blade bracket 2 Tighten screws 3 Blade cracked 3 Replace all blades 4 Non approved speed control being used 4 Change to approved speed control 5 Light globe noisy 5 Adjust globe mounting screws 3 Excessive wobbling 1 Blade brackets not attached at proper 1 Carefully review Step 9 locations 2 Unb...

Reviews: