CAUTION:

1. Read entire instructions carefully before beginning

installation.

2. To avoid possible electrical shock, be certain electricity is

shut off at main panel before wiring.

3. All wiring must be in accordance with national and local

electrical codes. If you are unfamiliar with wiring, you
should use a qualified electrician.

WARNING:

1. To reduce the risk of fire or electrical shock, do not use a

solid state speed control with this fan. Use Hunter Control
Model 22691.

2. To reduce the risk of personal injury, do not bend the blade

brackets when installing the brackets, balancing the blades
or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.

Step 1: Pre-Installation Instructions

A.

Select installation site. Check to make sure that in normal

use no object can come in contact with the rotating fan blades.
The mounting site should also meet the precautions listed in
Step 3 below.

B.

Installation hardware is included for a standard drywall or

plaster ceiling. You will need a 4" x 1

1

2

" or 4" x 

1

2

" outlet box

and wire nuts (2) which can be purchased from any hardware
store or electrical supply house.

C.

The fan blades must be mounted at least 7' above the floor.

For maximum efficiency, they should not have any obstruction
(walls, posts, etc.) within 24" of the blade tips. See Figure 1 for
mounting distances.

Step 2: Inspection of Fan

A.

Unpack unit carefully to avoid any damage to the compo-

nents.

B.

Check for any shipping damage to the motor and the fan

blades. If more than one fan is being installed, keep the matched
and balanced fan blades in sets, as they were shipped. Should
one of the fan blades become damaged during shipment, return
all blades in the set for replacement.

C.

Check contents to be certain it contains a bag of parts.

Step 3: Installation of Outlet Box 
and Rough-In Wiring

CAUTION: Your Hunter ceiling fan with accessories can weigh
up to 35 lbs. The following precautions must be taken for safety
and to ensure that your fan is securely mounted to the ceiling.

• Be certain electricity is “OFF” at the fuse panel when

inspecting or repairing installation site.

• All wiring must meet local and national electrical codes.

• Do not mount directly to an unsupported ceiling or to an elec-

trical outlet box. Mounting must support a 35 lb. fan with
accessories.

A.

Secure a metallic outlet box 4" x 1

1

2

" or 4" x 

1

2

" deep to

2 x 4 cross brace between two ceiling joists as shown in
Figure 2. The outlet box must be recessed in the ceiling by 

1

16

"

minimum. Secure the outlet box to the cross brace by drilling
(2) pilot holes no larger than the minor diameter of the wood-
screws (

5

64

") and use two #8 x 1

1

2

" woodscrews and washers.

Use the innermost holes for securing the box. Orient the box so
the outermost holes are aligned with the 2 x 4 brace. The outer-
most holes will be used in Step 4B.

CAUTION: Do not use a lubricant on screws.

B.

Bring electrical cable into the outlet box and attach with an

approved connector. Make certain that wiring meets all national
and local electrical codes. Wire leads should extend at least 6"
beyond outlet box for ease in making connections. See Figure 3.

INSTALLATION INSTRUCTIONS

FOR HUNTER CEILING FANS USING INSTALLER’S CHOICE MOUNTING

READ AND SAVE THESE INSTRUCTIONS

2 X 4 WOOD BRACE

OUTLET BOX

CEILING

CEILING JOIST

FIGURE 2

#8 WOODSCREW 
& WASHER (2) REQUIRED

CONNECTOR

FIGURE 3

6" MIN. LEAD LENGTH

24"

8' MIN.

CEILING

TO

FLOOR

7' MIN. 

TO FLOOR

FIGURE 1

CLEARANCE 

TO OBSTRUCTIONS

Summary of Contents for 40955-01

Page 1: ... shipped Should one of the fan blades become damaged during shipment return all blades in the set for replacement C Check contents to be certain it contains a bag of parts Step 3 Installation of Outlet Box and Rough In Wiring CAUTION Your Hunter ceiling fan with accessories can weigh up to 35 lbs The following precautions must be taken for safety and to ensure that your fan is securely mounted to ...

Page 2: ... the space B Next secure the canopy to the top of the fan using 3 10 32 screws with lockwashers packaged with the adaptor kit Make certain the screws are tight Failure to do so could result in the fan falling CAUTION To ensure proper engagement of the canopy assem bly screws the canopy must fit snug against the top of the fan CAUTION Do not lift motor by wires C Being careful not to scratch the ca...

Page 3: ...n until ceiling plate mounting screws are seated in bottom of slots in canopy Rotate fan counterclockwise until both mounting screws drop into slot recesses Tighten screws securely Install third screw into mounting hole CAUTION Failure to securely assembly the canopy screws could result in the fan falling NOTE For the handing fan configuration rotate fan until groove in ball is positioned over tab...

Page 4: ... kit This plate is pro vided with those fans which need it It should be installed as shown in Figure 10 If the switch housing on your fan is 31 4 diameter or less you do not need the adaptor mount the light kit directly to the switch housing Step 10 Operation of Fan A Turn electrical service on at main panel B Switch operates in this sequence High Medium Low OFF Pull chain slowly to operate Also r...

Page 5: ...eplace fuse 2 Loosen canopy Check all connections Turn power off while checking 3 Push switch firmly to one side or the other 4 Pull switch chain 5 Remove shipping blocks 1 Tighten screws until snug 2 Tighten screws 3 Replace all blades 4 Change to approved speed control 1 Carefully review Step 8 2 Use balancing kit See Step 8E 3 Lower or move fan 4 Tighten all screws 5 Turn power off support fan ...

Page 6: ...HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS TN 38114 1991 HUNTER FAN CO ...