ERROR CODES _______________________________________________________________________________
The machine shuts down and the display starts blinking. This
means that the software has detected an error in the system. The
numbers on the displays tell you what error has occurred. The
speed display will show the error level. The top temperature display
will show the error data. These displays are used to find the
problem. (The bottom temperature display shows the current
running program number.) The first time an error occurs on your
machine, reset your power by depressing and resetting the
Emergency stop button. If the error occurs again, see the chart. The
chart defines some of the problems that may have caused the error.
If you cannot define the problem, contact your distributor or sales
representative for technical assistance.
Note
:
After an error has shut down the system, the power must be
turned off for 10 seconds, using the Emergency stop button. After 10
seconds, turn the power on to restore the system.
*
WARNING!
The machine must be unplugged from the power
source before any servicing.
Speed Display
Top Temp Display
Problem
Error Level 1.0
Error Data 1
The photo-eye has
failed.
Error Level 1.0
Error Data 5
The digital I/O (DIO)
card is defective.
Error Level 2.0
Error Data 0
Reset. If error occurs
again, the digital I/O
(DIO) card is defective.
Error Level 2.1
Error Data 1
The Solid State Relay
for the top main roll
heater is defective.
Error Level 2.1
Error Data 2
The Solid State Relay
for the bottom main
roll heater is defective.
Error Level 2.1
Error Data 3
If the rollers are hot,
the Digital I/O (DIO)
card has failed. If the
rollers are cold, The
Analog Card has
failed.
Error Level 2.2
Error Data 1
The top thermocouple
is defective or has a
bad connection.
Error Level 2.2
Error Data 2
The bottom
thermocouple is
defective or has a bad
connection.
Error Level 2.2
Error Data 3
The Analog I/O (AIO)
Card is defective.