- 22 -
CLEANING AND MAINTENANCE
n
Do not use an abrasive cleaner on any surface of
your laminator.
n
Do not let water get onto the laminator. Water may
enter the electrical circuits and cause injury to
persons or damage to the laminator.
n
Use an Image Roller cleaner to remove excess
adhesive. This is done while the rollers are hot.
When cleaning the top roller, place a piece of foam or
paper under it to keep waste adhesive from falling
onto the bottom roller.
n
For a thorough cleaning, allow the rollers to cool and
then use isopropyl alcohol. Use a clean cloth.
*
Warning!
When using isopropyl alcohol, the rollers
must be cold. Isopropyl alcohol is flammable.
TECHNICAL ASSISTANCE
For Technical assistance, please contact your distributor.
When servicing, authorized technicians must disconnect
the power before removing side covers.
*
Warning!
Electrical shock hazard inside!
TROUBLESHOOTING
*
Warning!
The temperature readings will be affected
by high amplitude radio waves above 80MHz. If
fluctuation occurs, please contact your distributor or
technical service representative.
Problem – The machine will not turn on.
n
Make sure that the emergency stop buttons were not
activated. Rotate to reset.
n
Check the circuit breakers on the under side of the left
side plate.
n
With the power disconnected, check the fuse in the
power supply. This should be done by authorized
safety or maintenance personnel.
Problem – The Motor will not turn.
n
Check the motor circuit breaker. Refer to page 23 for
location.
n
Make sure that the photo eyes are not blocked.
n
With the power disconnected, check the fuse in the
motor control. This should be done by authorized
safety or maintenance personnel.
Problem – The machine is not heating up.
n
Make sure the heaters are turned on. Check for the
LED to be illuminated on the control panel.
n
Check the circuit breakers on the under side of the left
side plate.