5.2.14 Sensor NO/NC Settings
Command Code 23
Sets NO/NC settings for exit button and door sensor. Kindly refer to
the table below for the list of settings.
Function Table
Function Code
Action
Value
0
Exit Button “NC”
0
Exit Button NO/NC
+1
Exit Button ”NO”
1
0
Door Sensor ”NO”
0
Door Sensor
NO/NC
+4
Door Sensor ”NC”
4
Example
:
Exit Button as NO
,
Door Sensor as NO 1+0=1.Enter 1 to perform the mentioned functions.