background image

Revised Version:

 Ver 5.1

Applicable Wind Generator Model: 

HUMMER-3KW/5KW/10KW

Wind Generator and Yaw Shaft

 

 

 

Manual

Manual

ANHUI

 

HUMMER

 

DYNAMO

 

CO

.,

LTD

Summary of Contents for HUMMER-10KW

Page 1: ...Revised Version Ver 5 1 Applicable Wind Generator Model HUMMER 3KW 5KW 10KW Wind Generator and Yaw Shaft Manual Manual ANHUI HUMMER DYNAMO CO LTD ...

Page 2: ...o install your wind turbine by yourself You will find our great efforts to satisfy your requirements in the aspects of design manufacture operation applicability etc Please keep the manual carefully for further reference If you have any questions or comments we would like to hear from you Again thanks for your purchase and wish you enjoy the convenience that HUMMER wind generator brings you Thanks...

Page 3: ...UMMER 3KW Wind Generator Power Curve 5 2 HUMMER 5KW Wind Generator Power Curve 5 3 HUMMER 10KW Wind Generator Power Curve 6 Technical Parameters 7 Wind Generator Assembly 7 1 Blades Assembly 7 2 The Connection of the Generator Body and Yaw Shaft 7 3 The Connection of the Generator and Tower 7 4 Assembly of the Support and Dogvane 7 5 Assembly of the Lightning Rod 7 6 Assembly of Yaw Shaft Protecti...

Page 4: ...atch Dogvane Seal cover Yaw shaft protection cover DC24V direction regulating motor Speed reducer of DC24V motor Gear box Signal wire terminal block Relay DC24V power supply Yaw shaft angle sensor Generator rotational speed sensor Lifting loop for 5 10KW Generator temperature transducer Wiring terminal for Generator output cables Tower HUMMER 3 5 10KW wind generator is directly driven by rotor bla...

Page 5: ... receive any wind energy hence stop running when parallel to the wind direction 2 3 Wind Generator Direction regulating When blades rotate too fast owing to high wind speed the controller will alarm for over speed And the controller will drive DC 24V direction regulating motor with yaw shaft to deflect wind direction about 30 If the blades still rotate too fast the controller will further drive bl...

Page 6: ...facing wind Deflecting 30 from facing wind Route of yaw shaft 3KW 5KW 10KW 120s 10s 30s 150s 15s 40s 1 2 3 300s 25s 75s 2 6 Schematic Circuit of Wind Generator Control L N AC220V or DC160 DC300V SIEMENS CPU Wind generator Temperature sensor of wind generator Generator rotation speed sensor Yaw shaft deflection angle sensor Dogvane sensor DC 24V direction regulating motor Anemometer sensor Temperat...

Page 7: ...peed reducer Relay DC24V power supply II Dogvane signal wire Dogvane Dogvane signal wire Generator output cable connector inter changeable Signal Wire Connectors Signal Wire Connectors Generator rotation speed wire Generator temperature wire Output cable of generator Name Terminal Connect to Temperature Transducer Output cable connectors Temp1 Temp2 Temp3 T T U V 2 3 1 5 4 6 7 Signal wire connecto...

Page 8: ...ter converting The last one is for the signal transmission for the whole system with specification of 8 0 3 mm 7 of them are respectively used for 24V DC direction regulating motor to rotate clockwise or anti clockwise generator rotational speed signal generator temperature signal yaw shaft angle signal dogvane signal and GND power wire V the rest one is for spare use y 3 Cable for Transmission an...

Page 9: ... DC24V by the DC24V power supply in the yaw shaft and supplied to the direction regulating motor through the relay which is under the control of HUMMER controller might reach up to 250W If the consumed power is more than 250W the controller will protect it automatically and cut off the power supply to direction regulating motor And power will be supplied again in 120 seconds ...

Page 10: ...power W Charging voltage V Rotor blade diameter m Start up wind speed m s Rated wind speed m s Rated rotating rate r min Wind energy utilizing ratio Cp Rated charging current A The maximum charging current in a short time A Output AC frequency Hz Generator efficiency Tower height m Generator weight kg 12V 120Ah or 200Ah battery 6 Technical Parameters 6 1 HUMMER 3KW Wind Generator ...

Page 11: ...Generator weight kg 12V 150Ah or 200Ah battery 6 2 HUMMER 5KW Wind Generator 10000 15000 DC 240V Φ8 3 10 200 0 4 41 7 65 0 280 0 85 Wireless tower 15m Guyed tower 12m 287 20 pieces Rated power W Maximum output power W Charging voltage V Rotor blade diameter m Start up wind speed m s Rated wind speed m s Rated rotating rate r min Wind energy utilizing ratio Cp Rated charging current A The maximum c...

Page 12: ... fixing flange Outer hexagonal bolt Sponge cushion Generator CAUTION The side marked with FRONT shall be adown and windward All the 3 rotor blades have passed balance test and they need to be used together Please do not disorderly use the blades belonging to other wind generators 7 1 1 HUMMER 3KW Pull a steel wire through any of the holes on the generator connection base Use crane to take out the ...

Page 13: ... outer hexagonal bolts 3KW M14 55 5KW M18 80 10KW M18 90 and then fasten the nuts tightly Outer hexagonal bolt Focus the holes on generator connection base with those on yaw shaft Then connect and fasten them with bolts 7 2 The Connection of Generator Head and Yaw shaft 7 2 1 Lifting the Yaw Shaft Put steel wires through the lifting hole under the yaw shaft soleplate Lift the yaw shaft with the cr...

Page 14: ...e thin wires in the generator temperature signal cable Connect the one marked Temp 1 to the top terminal block on the temperature transducer and the other two Temp2 Temp3 to the below terminal blocks as shown in the following pictures T T Generator temperature wire Temperature transducer 7 3 The Connection of Generator and Tower 7 3 1 Drive the cable under the yaw shaft through the tower and pull ...

Page 15: ...rt into the seal cover and tighten them Put the protection cover to yaw shat horizontally Water proof seal ring and seal cover 7 4 4 Hold up the protection cover then put in the dogvane cable from the top of the support and pull it out from the bottom of the support Connect the three thin dogvane data wires W Direct V V to the corresponding terminal on the signal wire connector 7 4 5 Put dogvane o...

Page 16: ...nto the support 7 5 Assembly of the Lightning Rod If you selected the lightning rod please fix the lightning rod onto the yaw shaft plate when you assemble the dogvane support 7 6 Put on the yaw shaft protection cover fix it to the yaw shaft with cross screw Tighten the water proof cover along the dogvane support and lightning rod Cross screw for fastening of the yaw shaft ...

Page 17: ...rectified different model collocates different numbers of batteries please follow the suggested battery information in the user s manual And make sure the voltage of batteries matches with the output voltage of wind generator If batteries voltage is too high or too low the generator system may work improperly or some parts of the system could be burn out 8 4 Collocation of Batteries 8 4 1 HUMMER 3...

Page 18: ...ransmission Cables Inspection Check whether the connecting points of the cables arewell connected and whether any corrosion exists 9 4 Battery Maintenance Regularly check and maintain the batteries bank as per the maintenance requirements of the batteries If there is no wind for a long time don t let the batteries in electric deficit state for too long Charge it with grid power in time 10 Safety T...

Page 19: ...output cable are short circuit 2 Change the generator Check whether the output cables are open circuit or fuses are melted down Or get the fuse replaced 12 Annex Anemometer Assembly 12 1 Please refer to the steps of the dogvane assembly Pull the anemometer cable through the support firstly and then fasten the anemometer to the support with a screw 12 2 Settle the anemometer support to a place near...

Page 20: ...ales Fax 86 551 3442991 Customer service 86 551 5314300 E mail sales scfwindturbine com Website www scfwindturbine com 14 HUMMER Disclaimers The information in this manual is authentic and reliable However HUMMER assumes no responsibilities for expression inaccuracies or reasonable omission or for customers misunderstanding of the information or improper use of the product or for damage or injury ...