Page 1: ...HuMANDATA LTD Spartan 3A FPGA Board XCM 305 Series User s Manual Ver 1 2...

Page 2: ...fications 2 2 Overview 3 2 1 Name of Parts 3 2 2 Block Diagram 4 2 3 Power Supply 4 2 4 JTAG Connector 5 3 Configuration Switch 6 4 FPGA Configuration 7 5 Configuration Device Programming 7 6 Configur...

Page 3: ...to honor the warranty as through repair replacement return or other action The customer cannot specify what action to take 5 FPGAs and other components used in products sometimes have characteristic d...

Page 4: ...of pins of accessory pin header Mar 4 2013 1 2 Resister R5 is removed to separate VIO B from V33A Introduction Thank you for buying our product XCM 305 This is an evaluation board equipped with a Xili...

Page 5: ...Status LEDs 2 POWER DONE Power On Reset 240 ms typ Configuration Reset Signal JTAG Connector SIL 7 pin socket 2 54 mm pitch Power Input DC 3 3 V Internal power is generated by an on board regulator P...

Page 6: ...Series v1 2 2 Overview 2 1 Name of Parts Component Side Solder Side Status LEDs JTAG Oscillator 50 MHz User LED User Switch Config Switch User I Os CNA Power POR Serial I F FPGA MRAM User I Os CNB Con...

Page 7: ...p 240 ms PROG_B Config Switch Power Circuit 1 2 V Power LED 3 3 V User I Os CNB V IO B INPUT User I Os CNA 3 3 V INPUT 28 28 MRAM 4Mb 256Kx16 User Switch 2 3 Power Supply This board operates from sing...

Page 8: ...FPGA and program the configuration device in system Pin assignment is as follows CN3 Signal Name Direction JTAG Pin GND I O 1 TCK IN 2 TDO OUT 3 TMS IN 4 VCC OUT POW 5 TDI IN 6 GND I O 7 You can use X...

Page 9: ...ation Mode Suspend Mode Configuration Mode X_M0 X_M1 X_M2 Master SPI OFF ON ON JTAG OFF ON OFF 1 Target select OFF JTAG FPGA ON Configuration Device SPI PROM 2 4 Configuration Mode Select Master SPI M...

Page 10: ...an generate mcs file using ISE Please refer to the following steps Generating mcs file 1 Double click PROM File Formatter in Configuration Modes tab 2 Select 3rd Party SPI PROM for target and choose M...

Page 11: ...ate Programming File menu in Processes then click Properties 2 Change Configuration Rate value in Configuration Options 7 Additional Documentation and User Support The following documents and other su...

Page 12: ...es User s Manual Ver 1 2 Mar 4 2013 HuMANDATA LTD Address 1 2 10 2F Nakahozumi Ibaraki Osaka Japan ZIP 567 0034 Tel 81 72 620 2002 Japanese Fax 81 72 620 2003 Japanese English URL http www hdl co jp e...