Hugyfot Vision Xs HDMI Monitor User Manual Download Page 1

MADE IN

MADE IN

BELGIUM

Vision X

S

HDMI Monitor

w

w

w

.hu

g

y

fot

.com

Hugyfot User Manual

Summary of Contents for Vision Xs HDMI Monitor

Page 1: ...MADE IN MADE IN BELGIUM Vision XS HDMI Monitor www hugyfot com Hugyfot User Manual ...

Page 2: ......

Page 3: ...overview 6 4 Monitor sun hood 7 5 Opening the housing 7 6 Installing the monitor 8 7 Closing the housing 9 8 Installing the HDMI cable 10 9 Adjusting the monitor 11 10 Charging the battery 12 11 Maintenance 12 12 Accessory Armball installation 14 Maintenance Log 16 Hugyfot User Manual Vision XS HDMI Monitor ...

Page 4: ...rience this company has built in the field of metal working and constructional engineering is implemented in the housings production process Hugyfot introduces the HugyCheck system in 2009 This pre dive check system enables the photograper to perform a vacuum test prior to entering the water This test indicates whether the housing has been closed properly and whether the housings O rings are in go...

Page 5: ...rs approximately 3 hours battery life while photographing and 2 hours while filming The Hugyfot Vision Xs HDMI Monitor is designed to work with the HugyCheck pre dive vacuum check system but is also fully compatible with all other pre dive systems thanks to the HugyCheck Vacuum HDMI Connection which comes standard with the monitor This HugyCheck Vacuum HDMI Connection transfers the HDMI signal and...

Page 6: ...tank pressure and decompression limits at all times Your Hugyfot Vision Xs underwater housing is designed to withstand depths of up to 490 feet 150 meters well beyond recreational dive limits as well as most technical dive depths Stay within safety dive limits in keeping with your level of certification and expertise Do not use your Hugyfot Vision Xs housing at depths beyond your training level an...

Page 7: ...bag or an airtight case Allow your housing to acclimate then remove it from the bag or case To reduce risk of condensation do not open your housing between dives If condensation forms inside your Hugyfot Vision Xs housing do not use it Open your housing remove the camera battery packs and allow condensation to completely evaporate before using it Following any extended period of storage check that...

Page 8: ...buttons 3 Closing latches 4 Monitor sun hood 5 1 Armball 6 HugyCheck Vacuum HDMI Connection 7 M16x1 Port 8 M6 thread for optional 1 Armball 9 Sacificial Zink Anode 10 Feelworld F5 4K 5 HDMI monitor with battery 11 Battery Release Button 12 HDMI Cable 13 Internal micro HDMI to HDMI connection link 14 M15x1 5 or M16x1 HDMI Bulkhead as ordered 15 HDMI Bulkhead Cap ...

Page 9: ...ng latches You only need to open the housing to install a freshly charged battery or to remove the used depleted battery Opening the housing 1 Release the vacuum if applicable from the camera and monitor system Without releasing the vacuum it is impossible to open the housing 2 Either place the housing on a flat stable surface with the monitor with installed sun hood faced down or leave it install...

Page 10: ...ing and 2 hours when filming 1 Open the housing as described in chapter 6 2 Snap the battery onto the monitor The monitor accepts 2 types of batteries for Sony type batteries insert in the middle with the battery contacts pointed to the left and slide towards left for Canon type batteries you have to point the contacts to the right and slide to the right with the monitor faced buttons up 3 To rele...

Page 11: ... this in section 12 Maintenance 2 When closing the lid pay particular attention to the routing of the HDMI cable It needs to bend inside the housing make sure it is not caught between the shells This can result in unrepairable damage to the cable 3 There is a notch in the hinged mechanism to guide the cable make sure the cable sits into this notch before closing the housing 4 Push both shells firm...

Page 12: ...correct sealing with if equipped a vacuum pre dive check system Follow the pre dive check system s guidelines to perform a correct sealing check If you don t have a pre dive check system you should perform a dive with the housing without camera and monitor installed The sealing of the monitor housing and HDMI connection cable have been factory pressure tested before shipping Please do not install ...

Page 13: ...details From left to right 8 controls are offered F1 F2 Left Right Menu Down Up Power 1 To access the settings press the menu button 2 You can travel through the menu sections by pushing the Left and Right buttons 3 We will now show you how to program the function buttons F1 and F2 Select the last section marked F by pushing either Left or Right button Press the Down button to enter into the menu ...

Page 14: ...g Don t pull or stretch it Your fingers are the best way to determine the presence of unwanted particles If available run your O rings under the faucet Use room temperature tap water carefully removing unwanted particles by rubbing one O ring at a time between your fingers If needed feel free to apply a dab of dish soap tho roughly rinse under the faucet then let your O rings air dry Discard and r...

Page 15: ...Disassembly should only be performed in case of malfunctioning or periodic maintenance Following instructions should only be performed by persons with experience in fine mechanics Damaged HDMI connections are never subject of manufacturer s warranty and are expensive to replace Please send your monitor housing and HDMI cable for service to an accredited Hugyfot service center if needed 1 Remove th...

Page 16: ...Hugyfot User Manual Vision XS HDMI Monitor 14 1 4 5 6 9 8 7 2 3 ...

Page 17: ...old a focus light in the M6 mount hole on the backside of the monitor housing Hugyfot M6 Armballs are provided with 2 straight edges that prevent the Armball from turning so no glue or excessive tightening force on the bolt is needed Excessive force can damage the Aluminum M6 thread and is not covered by manufacturer s warranty 10 11 12 ...

Page 18: ... full service Quality control pressure test Vision XS HDMI Monitor Maintenance Log Housing serial number Date Date Date Factory Quality control pressure test date Hugyfot Service Center Hugyfot Service Center Hugyfot Service Center Stamp Stamp Stamp Stamp ...

Page 19: ......

Page 20: ...Hugyfot BV Rietstraat 63 9320 Erembodegem Belgium www hugyfot com info hugyfot com ...