![Hubner FG 2 Series Operating And Assembly Instructions Manual Download Page 17](http://html1.mh-extra.com/html/hubner/fg-2-series/fg-2-series_operating-and-assembly-instructions-manual_2180891017.webp)
Incremental Encoder FG 2
FG2_MANUAL-en_R8(2016-08-11)ID70199.doc
17
6.6
Mounting tolerances
NOTES!
Angle misalignment and parallel displacement between the (motor) shaft and the
encoder shaft are mounting errors and should be kept as small as possible.
Mounting errors
- Cause radial forces to act on the encoder shaft.
- Reduce the service life of the bearings and the coupling.
- Degrade the quality of the signals (harmonic content).
Mounting tolerances for our zero-backlash, torsion-resistant couplings HK 5 and HKD 5:
Coupling
Axial offset
a
Angular error
α
Parallel offset e
HK 5
± 1 mm
0.5°
-
HKD 5
± 1.5 mm
0.5°
0.5 mm