background image

COUNTER TOP REFRIGERATION

MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB

HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

Service, Installation and Care Manual

Please read this manual completely before attempting to install or operate this equipment. 

Notify carrier of damage!  Inspect all components immediately. See page 2.

IMPORTANT INFORMATION 

READ BEFORE USE 

PLEASE SAVE THESE INSTRUCTIONS!

031816 

HUBM-3.5RB 

 

 

  HUBM-3.5FB

HUBM-2RB 

   

HUBM-2FB

HUBM-3.5R 

 

 

   HUBM-3.5F

HUBM-2R    

HUBM-2F

Summary of Contents for HUBM-2F Series

Page 1: ...ion and Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 IMPORTANT INFORMATI...

Page 2: ...care should be taken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be not...

Page 3: ...B HUBM 2R Refrigerator 120 60 1 1 5A 2 4 Cu Ft 67 96 L 1 16 495 3 5 Oz 0 09 Kg 95 lb 5 15P HUBM 2FB HUBM 2F Freezer 120 60 1 2 0A 1 7 Cu Ft 48 13 L 1 16 341 6 oz 0 17 Kg 95 lb 5 15P HUBM 3 5RB HUBM 3...

Page 4: ...2 from any wall with at least 12 of clear space above the unit LEVELING A level cabinet looks better and will perform better because the doors will line up with the frames properly Use a level to make...

Page 5: ...y setting of the temperature range is 35 to 41 F FREEZERS 1 Anti Condensation heaters on the door frames work in conjunction with the compressor 2 The factory setting of the temperature range is 3 to...

Page 6: ...wn through with compressed air Failure to maintain a clean condenser coil can initially cause high temperatures and excessive run times Continuous operation with dirty or clogged condenser coils can r...

Page 7: ...rength cleaning products on gaskets as this can cause them to become brittle and prevent proper seals Do not use sharp tools or knives to scrape or clean the gasket which could possibly tear the gaske...

Page 8: ...as well as in written form 4 Request an inspection by the shipping company of the damaged equipment This should be done within 10 days from receipt of the equipment 5 Be certain to check the compresso...

Page 9: ...9 Service Installation and Care Manual WIRING DIAGRAM HUBM 2RB HUBM 2R HUBM 2FB HUBM 2F...

Page 10: ...10 Service Installation and Care Manual WIRING DIAGRAM HUBM 3 5RB HUBM 3 5R HUBM 3 5FB HUBM 3 5F...

Page 11: ...11 Service Installation and Care Manual NOTES...

Page 12: ...800 543 7374 www hubert com...

Reviews: