Hubbell PERIMALITER III Installation Instructions Manual Download Page 1

PERIMALITER III  AND PERIMASHIELD III

INSTALLATION INSTRUCTIONS

SEE WARNING ON CARTON

WARNINGS:

This product contains chemicals known to the state of California to cause cancer, birth

defects and/or other reproductive harm. Thoroughly wash hands after installing,

handling, cleaning, or otherwise touching this product.

Read and follow the lamp manufacturer’s warning and use information before installing

or relamping this light fixture.

Disconnect power before installing or servicing.

Install, operate and maintain to meet all applicable codes.

Protect all wiring connections with approved insulators (by others).

Selected fixture voltage must match supply line voltage.

GENERAL INFORMATION, JUNCTION BOX MOUNT:

Allow 6” (152.4 mm) minimum supply wire outside of junction box.

Use two 5/16” (7.925 mm) dia. min. hardware (by others) to mount fixture.

GENERAL INFORMATION, CONDUIT MOUNT:

All 12” (304.8 mm) minimum supply wire outside of conduit.

Housing conduit threads are ½-14 NPS.

Use two 5/16” (7.925 mm) dia. Min. hardware (by others) to mount fixture.

Use a waterproof pipe joint compound (by others) for all entries into housing.

Plug all unused entries into housing.

GENERAL INFORMATION: INSTALLATION INSTRUCTIONS –

PHOTOCONTROL

1.

Remove raceway cover (5) and reflector (3).

2.

Loosen Ballast cover retaining screws (11) and remove Ballast cover (12).

3.

Remove ½-14 NPS conduit plug (10) located at top of fixture.

4.

Install (PBT) photocell gasket and insert photocell from inside thru housing and

extending outward as far as possible. Secure with black plastic nut.

5.

Select ballast voltage lead which matches supply voltage and connect to red load lead

from photocell.

6.

Connect supply voltage lead to black lead from photocell.

7.

Connect Common from photocell, Common lead from ballast and Supply Common lead

together.

8.

Connect Green ground lead from fixture to Supply Ground lead.

9.

Protect all unused leads having exposed wire with approved insulators.

10.

Replace raceway cover being careful to avoid pinching wires.

11.

Replace reflector.

12.

Close refractor door and secure with two screws.

JUNCTION BOX MOUNT: (See Figures 1, 2, and 3)

1.

Loosen lens retaining screws (1) and remove lens.

2.

Loosen reflector screws (2) and remove reflector (3).

3.

Drill or knockout two 3/8” (9.525 mm) holes at boss locations (6) on casting.

4.

Locate and drill mounting holes using template provided.

5.

Mount fixture to wall.

6.

Apply RTV around wall casting top and (2) sides.

7.

Temporarily remove rubber hole plug (7). Push wires from inside of Fixture through

hole plug into junction box.

8.

Make wiring connections. Push wires and connections into junction box.

9.

Make sure that ends of unused voltage leads are capped and pushed inside raceway

cover (5).

10.

Replace rubber hole plug as it was before. Do not pinch wiring.

11.

Replace reflector with large keyway hole toward bottom of fixture.

12.

Remove clear adhesive cover from reflector and discard. Tighten retaining screws.

13.

Install lamp.

14.

Replace lens and tighten retaining screws.

CONDUIT MOUNT: (See Figures 1, 2, and 3)

1.

Follow Steps 1-6 listed above.

2.

Loosen raceway cover retaining screw (4) and remove raceway cover (5).

3.

Thread conduit to fixture.

4.

Make wiring connections. Place all connections in raceway area.

NOTE: For thru wiring, supply wires to be placed under reflector for PGM 250W thru 

wire, use the (3) 140

o

C Jumper wires and wire nuts provided. Route Jumper wire

under reflector. Make supply wire connections under raceway cover (5).

5.

Make sure that ends of unused voltage leads are capped and pushed inside raceway.

6.

Replace raceway cover and tighten retaining screw.

7.

Follow Steps 10-13 listed above.

Hubbell Lighting, Inc.

Doc. No. 93020703

A subsidiary of Hubbell Incorporated

701 Millennium Drive • Greenville, SC 29607

Phone (864) 678-1000

Outdoor Lighting

®

WIRING DIAGRAM

FIXTURE

GROUND

COMMON

VOLTAGE

GREEN/GROUND

NEUTRAL

LINE (HOT)

1

APPLY RTV SEALANT AROUND

CASTING TOP AND (2) SIDES

10

FIGURE 1

FIGURA 1

FIGURE 2

FIGURA 2

FIGURE 3

FIGURA 3

LARGE HOLE

AGUJERO GRANDE

GROS TROU

6

7

2

3

4

5

THRU WIRING (BEHIND REFLECTOR)

INSTALACIÓN DE CABLEADO CONTÍNUO

(DETRÁS DEL REFLECTOR)

INSTALLATION À FILAGE CONTINU

(DERRIÈRE LE RÉFLECTEUR)

12

11

11

LOAD

LINE

COM P.C.

COM (WHT)

LINE (BLK)

LINE V

COM

BALLAST

PRIMARY

ADJUSTABLE OPTICS: (See Figures 4)

Loosen socket retaining screws.

Repositioning socket.

1.

2.

3.

Tightening socket retaining screws.

The PERIMASHIELD features adjustable cutoff. The adjustment can be made by:

FIGURE 4

FIGURA 4

MAX

MIN

MÁX

MIN

MAXIMUM CUTOFF

CORTE DE HAZ MÁXIMO

COUPE-FAISCEAU MAXIMUM

MINIMUM CUTOFF

CORTE DE HAZ MÍNIMO

COUPE-FAISCEAU MINIMUM

Industrial Lighting 