NX LIGHTING CONTROL PANEL RELAYS
Page
2/2
Rev.
03/17/21
3483A_NXP2-RL_SPEC
DATE:
LOCATION:
TYPE:
PROJECT:
CATALOG #:
© 2021 Hubbell Control Solutions, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / hubbellcontrolsolutions.com
DIMENSIONS
4.5"
(49.5mm)
2.40"
(60mm)
3.54"
(90mm)
3.78"
(96mm)
ON
BLUE
RE
D
4.19"
(106.5mm)
0.96"
(24.5mm)
2.40"
(60mm)
3.54"
(90mm)
Blue
Red
ON
Double Pole Relay
Single Pole Relay
Relay Wiring Diagrams
SIMLXRL1 - Simplicity LX Single Pole Relay
SIMLXRL2 - Simplicity LX Double Pole Relay
Installation Instructions
Hubbell Building Automation, Inc.
9601 Dessau Road • Building One • Suite 100
Austin, Texas 78754
512-450-1100 • 512-450-1215 Fax
This document provides instructions for installing and connecting Single and/or Double Pole Relays in the Simplicity LX Series Lighting
Control Panel.
Contents
These instructions include information as follows:
Description
General Precautions
Installation
Precautions
• Read and understand all instructions before beginning installation.
• For installation by a qualified electrician in accordance with National and/or local Electrical Codes and the following instructions.
•
RISK OF ELECTRICAL SHOCK.
Turn power off at breaker panel before servicing unit. Never wire energized electrical components.
Never operate unit with door panel or relay guards removed.
•
USE COPPER CONDUCTOR ONLY.
• Confirm that device ratings are suitable for application prior to installation.
• Use only approved materials and components (i.e. wire nuts, electrical box, etc.) as appropriate for installation.
•
NOTICE:
Do not install if any damage to product is noticed.
Installation
1. Verify that power is turned off at breaker panel before installing relay in panel.
2. Remove panel door assembly from panel enclosure.
3. Locate an open relay position (two adjacent positions for a double pole relay) in the panel and remove the relay guard cover(s).
4. Insert relay into mounting bracket noting proper orientation of input/output sides. Verify that relay is securely held in mounting bracket.
5. Connect relay input and output as shown in the wiring diagram below. Connect input to panel I/O control card using relay connector
cable. Attach red lead to red screw and blue wire to blue screw. Slide connector on to header pins of I/O control card. Connect line and
load leads to relay output.
Figure 1: Relay wiring diagrams
Load
(to lighting system)
Load, Phase 2
(to lighting system)
Load, Phase 2
(from Circuit Breaker)
Load, Phase 1
(to lighting system)
Load, Phase 1
(to lighting system)
Blue Input Screw
Blue Lead
Red Input Screw
Red Lead
Relay Connector
I/O control
Card Header
(Polarized)
Blue Input Screw
Blue Lead
Red Input Screw
Red Lead
Relay Connector
I/O control
Card Header
(Polarized)
Line
(from Circuit Breaker)
Single Pole Relay
Double Pole Relay
WIRING DIAGRAM