Pub. 42004-467D
Camera Telephone Manual
Page 10 of 30
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-467D.docx
04/19
Models 397-001CAM and 398-001CAM—Tower or Flush-Mount
Installations
The supplied back box must be used to mount the Model 397-001CAM or Model 398-001CAM
telephones for flush-mount installations or when mounting in a GAI-Tronics Model 234 Series Tower.
Figure 8. Model 397-001CAM
Figure 9. Model 398-001CAM
1.
Mount the back box to the structure using appropriate hardware (see Figure 10 for the cutout
dimensions).
N
OTE
:
The installation of a (customer-supplied) telephone line suppressor is recommended if the
telephone is mounted outdoors.
2.
Remove a tapered plug from either cable entry hole in the back box.
3.
Install the telephone line and cable fitting.
N
OTE
:
Telephone line connections directly to terminal block
TB1
are acceptable.
4.
If using the modular jack
:
1.
Remove the cover.
2.
Connect the telephone line’s tip (+) wire to the green wire on the modular jack.
3.
Connect the telephone line’s ring (−) wire to the red wire on the modular jack.
4.
Replace the modular jack cover.
5.
Connect the telephone’s modular plug to a USOC RJ11 or CA11A (Canada) modular connector or (if
applicable) the telephone line suppressor (see Figure 10).
An inline coupler is provided for use, if necessary.
6.
Connect the video cable to the video BNC connection (see Figure 7 and Figure 11).
7.
Connect 12 V dc power using the screw terminal connector (see Figure 7 and Figure 11).
N
OTE
:
Reference the CCD camera specifications for proper power supply requirements.
8.
Allow the telephone a minimum of 35 seconds to initialize.