ADA (Americans with Disabilities Act) Programming
The ADA features provide the following benefits:
•
C
ALL
R
ECEIVED
W
HEN
L
IT
indication - This lamp provides indication to hearing-impaired
individuals that the emergency call has been answered.
•
The Location Identification Code - This feature enables security personnel to quickly and easily
locate an individual in trouble.
•
DTMF Call Disconnect - Enables the security operator to disconnect the call by pressing ##.
N
OTE
:
These features do not apply to Models 392-001 and 392-001FS.
Table 9. Americans with Disabilities Act (ADA) Configuration
Feature
Key
Sequence
Description
Default
DTMF
Disconnect
Option
# 1 8
L
This option controls the DTMF “##” disconnect feature.
To enable, set
L
=1.
To disable, set
L
=0.
1 (Enabled)
Location
Identification ID
Setup
# 1 3
L N N N
This option enables and stores the three-digit location
identification ID number.
To enable the ID feature, set
L
=1.
To disable the ID feature,
L
=0.
Enter the three-digit location identification code in the
sequence
N N N
.
Example
: To enable the location ID feature and store the
three-digit ID code 357, enter
# 1 3 1 3 5 7
.
To disable the location ID feature, enter
# 1 3 0 0 0 0
.
N
OTE
:
The ADA options must also be enabled.
No default
setting. The
user must
complete this
step to have
the
identification
code
transmitted.
Extended Strobe Operation (Requires External Power Supply)
Output one can be programmed for extended operation (remain closed) for up to 255 minutes (in 1-minute
increments) after the emergency call ends.
Table 10. Extended Strobe Operation
Feature
Key
Sequence
Description
Default
Extended Strobe
Operation
# 2 5
N N N
Sets the duration of the activation of the Output 1 contact
starting at the end of a call. Use entries 001–255,
representing 1 minute to 255 minutes in 1-minute
increments.
Use 000 to disable this feature.
To set a duration of 7 minutes, enter
# 2 5 0 0 7
.
0 0 0