GAI-TRONICS
VoIP Telephone Configuration Guide
Page 21 of 78
System
Phone Maintenance
net syslog enable
Description:
Control to enable transmission of SYSLOG messages. Used by GAI-Tronics
TMA monitoring software, see section 11.
Basic or advanced: Basic
Range check: enabled / disabled
Default value: disabled
Default value differs with model variant? : N
Config file parameter name: net_syslog_enable
System
Phone Maintenance
net syslog server
Description:
Fully qualified domain name for the SYSLOG server. Reboot required after
update. Used by GAI-Tronics TMA monitoring software, see section 11.
Basic or advanced: Basic
Range check: max 64 chars
Default value:
Default value differs with model variant? : N
Config file parameter name: net_syslog_server
System
Phone Maintenance
net syslog server port
Description:
Syslog server port
Basic or advanced: Basic
Range check: max 11 chars
Default value: 514
Default value differs with model variant? : N
Config file parameter name: net_syslog_server_port
System
Phone Maintenance
net syslog facility
Description:
Sets the SYSLOG message facility level, as per RFC3164. Used by GAI-Tronics
TMA monitoring software, see section 11.
Basic or advanced: Basic
Range check: max 11 chars
Default value: 14
Default value differs with model variant? : N
Config file parameter name: net_syslog_facility