background image

OPERATION

"AC ON" LED is illuminated when AC power is present.

NOTE: All models are supplied with an AC Lockout Circuit, which prevents the "EXIT" legend from illuminating when the battery is connected and no AC power is present.

NOTE: All models are supplied with a Low Voltage Disconnect circuit, which prevents damage to the battery from deep discharge during prolonged emergency operation.

NOTE: Batteries are often shipped in a discharged state  this is normal.  The battery will require charging.  Allow several hours of charge before testing the unit.

Models With SPECTRON® SelfTesting/SelfDiagnostic Circuitry

Models equipped with the SPECTRON selftesting/selfdiagnostic electronics system provide:

■ Visual indication of AC power status

■ Visual indication of selfdiagnostic test cycle

Visual indication of any unit malfunctions including:

■ Battery disconect

 Battery fault          ■ Transfer fault          ■Charger fault          ■ Emergency Lamp fault

Spectron equipped units also include:

Brownout protection:  unit will automatically transfer to emergency operation upon detection of low AC power (aproximately 80% of normal line).

Time Delay Retransfer:   upon return of normal AC power, unit will remain in the emergency mode for an additional 15 minutes to allow AC power to stabilize.

LED Status Indicator

A bicolor LED (red/green) is provided on the control panel of all models equipped

with Spectron option.

Green Operating Status Indicator

The green Operating Status Indicator serves as both an AC power and selftest

indicator.  During normal operation, the green Operating Status Indicator will be

illuminated, indicating the presence of AC power.  During all automatic or manual

selftest cycles, the green Operating Status Indicator will blink at a 1 Hz rate.

Red Service Alert Indicator

Under normal operating conditions, the red Service Alert Indicator will remain off.

In the event the Spectron controller detects a malfunction, the red Service Alert

Indicator will blink at a 1 Hz rate, based on the following table:

Red Status Indicator Code Description

One blink ON/pause

Battery not connected

Two blinks ON/pause

Battery fault

Three blinks ON/pause

Charger fault

Four blinks ON/pause

Transfer circuit fault

Five blinks ON/pause

Emergency Lamp fault

Manual Tests

Using the unit test switch, users can initiate different duration test cycles

based on the following table:

Automatic Tests

The unit will automatically initiate a selftest/selfdiagnostic cycle based

on the following table:

Initiating Action

Test Cycle

Press test switch once

1 minute

Press test switch twice

90 minutes

Testing Period

Duration of Test

Once a month

1 minute

Once every 6 months

Alternating:
30 minutes or 60 minutes

MAINTENANCE

TROUBLE SHOOTING

●  "EXIT" legend does not illuminate

       check wiring connections

●  Emergency Circuit does not work

      Batteries are shipped uncharged and disconnected.  Connect power pack leads charge before testing.

      Make sure charger board is properly seated.

      Check wiring connections.

MAINTENANCE

Signs should be tested and maintained in accordance with National Electrical Code and NFPA 101 Life Safety Code requirements.  It is recommended that emergency exit

signs be tested for 30 seconds once a month and for 90 minutes once a year.

RECYCLING INFORMATION

All thermoplastic parts are recyclable.

All cartons contain recycled materials.

Please recycle responsibly.

NOTICE:

Emergency model exit signs contain rechargeable Nickel Metal Hydride batteries which must be recycled or disposed of properly.

Hubbell Lighting, Inc. Life Safety Products  •   www.duallite.com

Copyright© Hubbell Lighting, Inc., All Rights Reserved  •  Specifications subject to change without notice.  •  Printed in U.S.A.

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

1.  Do not use outdoors.

2.  Do not let power supply cords touch hot surfaces.

3.  Do not mount near gas or electric heaters.

4.  Equipment should be mounted in locations and at heights where it will not readily be subject to tampering by

     unauthorized personnel.

5.  The use of accessory equipment not authorized by the manufacturer may cause an unsafe condition.

6.  Do not use this equipment for other than its intended purpose.

7.  Servicing of this equipment should be performed by qualified service personnel.

8.  Test cycling:  the Life Safety Code (NFPA 101) requires testing of emergency exit signs once a month for a

     minimum of 30 seconds and once a year for a minimum of 90 minutes

.

INSTALLER:

• SEE UNIT LABLE FOR ADDITIONAL MODEL SPECIFICATIONS

• SAVE THESE INSTRUCTIONS FOR USE BY OWNER/OCCUPANT

WARNING  This product  contains chemicals known to the State of California to cause cancer, birth defects, and/or other reproductive harm.

Thoroughly wash hands after installing, handling, cleaning,  or otherwise touching this product.

EVE Series

Thermoplastic LED Exit Sign

Installation, Operation, and Maintenance Instructions

ALB

ALB

EC-160831001

9/15/16

1

4

3

D

C

B

A

4

3

2

1

D

C

B

A

1

2

REV

DATE

RECORD

DESN CHCK

SHT 1

1 SHTS

---

---

93075474

93075474

1

ILL-CTN EVE4X

ALB

09/15/16

ALB

9/15/16

---

ALB

9/15/16

1:1

REV.

DRAWING NO.

SIZE

SCALE

PART NO.

FINISH:

MATERIAL:

This document contains confidential and proprietary information of Dual

Lite. Receipt or possession of this document does not convey any rights to

reproduce or disclose its contents, or to make, use , or sell anything it may

disclose. Reproduction, disclosure, or use of the document or its contents,

without the specific written authorization of Dual Lite, may violate the

intellectual property rights of Dual Lite.

DIMENSIONS IN INCHES
DIMENSIONS IN [ ] IN MM
CONFORMS TO ASME Y14.5M
DO NOT SCALE PRINT

DRAWN BY:

THIRD ANGLE PROJECTION

CHECKED BY:

ENGINEERING:

CATALOG NO.

CRITICAL DIMENSIONS

C

UNSPECIFED TOLERANCES:    INCHES

X.X=±0.02   X.XX=±0.01   X.XXX=±0.005

FRACTIONS=±1/64   ANGULAR TOLERANCE=±.5°

THIS ILLUSTRATION TO BE USED ON INST:93075008

Emergency LED Exit Sign Listed for Wet locations

AC, Emergency & Spectron Emergency rated N4X/IP66

Installation, Operation, and Service Instructions

EVE4X Series

OPERATION

93075008 B 5/1/17

93075474

MAINTENANCE

IMPORTANT SAFEGUARDS

When using electrical equipment, basis safety precautions should always be followed 

including the following.

READ AND FOLLOW ALL SAFETY INSTRUCTION

1. Do not let power supply cords touch hot surfaces.

2. Do not mount near gas or electric heaters.

3. Equipment should be mounted in locations and at height where it will not readily

be subjected to tampering by unauthorized personnel.

4. The use of accessory equipment not authorized by the manufacturer may cause an 

unsafe condition.

5. Do not use this equipment for other than its intended purpose.

6. Servicing of this equipment should be performed by qualified service personnel.

7. Test cycling: the Life Safety Code (NFPA 101) requires testing of emergency exit signs 

once a month for a

minimum of 30 seconds and once a year for a minimum of 90 minutes.

INSTALLER

•  SEE UNIT LABEL FOR ADDITIONAL MODEL SPECIFICATIONS

•  SAVE THESE INSTRUCTIONS FOR USE BY OWNER/OCCUPANT

WARNING

: - This product contains chemicals known to the State of California to cause 

cancer, birth defects and/or other reproductive harm. Thoroughtly wash hands after 

installing, handling, cleaning or otherwise touching this product.

Reviews: