5.4
Testing the Splitter/Combiner
The splitter/combiner has three parameters which must be checked to verify correct operation: insertion
loss, isolation, and phase relationship.
Table 12 – Splitter/Combiner Characteristics
Splitter/Combiner Characteristics
Insertion Loss
IN 1 to LINE 1 ~6.5 dB
IN 1 to LINE 2 ~6.5 dB
IN 2 to LINE 1 ~6.5 dB
IN 2 to LINE 2 ~6.5 dB
Isolation (trans-hybrid loss)
IN 1 to IN 2
~20 dB
IN 2 to IN 1
~20 dB
Phase Relationship
IN 1 to LINE 1 0°
IN 1 to LINE 2 180°
IN 2 to LINE 1 180°
IN 2 to LINE 2 0°
To FSVM /
50-ohm termination
IN 1
SPL/COM
IN 2
LINE 1
LINE 2
50-ohm
dummy load
Signal In
50-ohm
dummy load
Figure 46 – Measuring Splitter/Combiner Insertion Loss, IN 1 to LINE 2