NOTE
Insert the optical fibers until they snap into place.
Step 9
Observe the port indicator to check whether the optical module is properly installed.
l
If the indicator is steady green or blue, the installation is successful.
l
If the indicator is steady red or off, the newly installed optical module is faulty, the port
for the optical module is faulty, or the optical module is incorrectly installed.
Step 10
Confirm the replacement.
1.
Perform a post-replacement inspection.
After the parts replacement, return to the SmartKit page and click
Replaced
. Then
complete the check after the replacement as prompted.
2.
Check system status.
On the
Parts Replacement
page, click
Inspection
to check the system status again. If
any inspection item fails, rectify the fault based on the suggestions in the inspection
report.
3.
After the preceding procedure is complete, check services on the host for any storage-
related error.
----End
Follow-up Procedure
After the optical module is replaced, label it to facilitate subsequent operations.
5.13 Replacing the Parts of a Data Switch
This section describes how to replace the parts of a data switch.
5.13.1 Replacing a Power Module
This section describes how to replace a power module.
Impact on the System
In the process of replacing a power module on a data switch, if the redundant power supply on
the data switch fails unexpectedly, the data switch will be powered off. As a result, the I/O
forwarding workload transfers to another switch, degrading the system reliability.
Prerequisites
l
The spare part is ready.
l
The power module that you want to replace has been located.
Precautions
l
Remove and insert a power module with even force. Excessive force may damage the
appearance or connectors of the power module.
l
Remove only one power module at a time.
l
After removing a power module, install a new one within two minutes. Otherwise, the
system heat dissipation is compromised.