Figure 5-80
Running/Alarm indicator on a power module
Step 10
Confirm the replacement.
1.
Perform a post-replacement inspection.
After the parts replacement, return to the SmartKit page and click
Replaced
. Then
complete the check after the replacement as prompted.
2.
Check system status.
On the
Parts Replacement
page, click
Inspection
to check the system status again. If
any inspection item fails, rectify the fault based on the suggestions in the inspection
report.
3.
After the preceding procedure is complete, check services on the host for any storage-
related error.
----End
Follow-up Procedure
After the power module is replaced, label it to facilitate subsequent operations.
5.9 Replacing a BBU
This section describes how to replace a BBU.
5.9.1 Replacing a BBU (for Dorado5000 V3)
This section describes how to replace a BBU.
Impact on the System
l
Replacing a BBU affects data security.
l
During the replacement, if all other BBUs fail, the system is no longer BBU-protected.
To enhance data security, the system forcibly implements LUN write protection, and the
system performance is compromised.
Prerequisites
l
The spare part is ready.
l
Configuration data has been backed up.
OceanStor Dorado V3 Series
Parts Replacement
5 Replacing FRUs
Issue 05 (2019-01-30)