background image

UPS2000-G-(1 kVA-3 kVA) Battery Pack 
Quick Installation Guide (2016, Russia) 

4 Connecting a Battery Pack and a UPS 

 

Issue 02 (2016-07-28) 

Huawei Proprietary and Confidential                                     

Copyright © Huawei Technologies Co., Ltd. 

15 

 

 

 

ESS-72V12-9AHBPVBB01 is allowed a maximum of three groups in parallel. The text 
uses two groups in parallel as an example. If four groups need to be connected, refer to the 
connection method of two groups. 

 

The battery pack has two output ports, as a parallel state, the same function. If one used to 
connect the UPS or battery pack, another can be used to connect an external charger. 

 

Before connecting, please make sure that the breaker of the battery pack is in the OFF 
state. 

Figure 4-3

 

Connection between the ESS-72V12-9AHBPVBB01 battery pack and a 3 kVA UPS 

 

Summary of Contents for UPS2000-G Series

Page 1: ... 2016 07 28 HUAWEI TECHNOLOGIES CO LTD Проконсультироваться и купить данное оборудование вы можете в компании АНД Системс адрес 125480 г Москва ул Туристская д 33 1 site https andpro ru тел 7 495 545 4870 email info andpro ru При обращении используйте промокод AND PDF и получите скидку ...

Page 2: ... Huawei and the customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this docum...

Page 3: ...l support engineers System engineers Hardware installation engineers Commissioning engineers Data configuration engineers Maintenance engineers Symbol Conventions The symbols that may be found in this document are defined as follows Symbol Description Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potentially hazardous situation ...

Page 4: ...not related to personal injury Calls attention to important information best practices and tips NOTE is used to address information not related to personal injury equipment damage and environment deterioration Change History Changes between document issues are cumulative The latest document issue contains all the changes made in previous issues Issue 02 2016 07 28 Added battery pack for 2 kVA UPS ...

Page 5: ...ry Pack for 1 kVA UPS 3 2 2 2 Battery Pack for 2 kVA UPS 4 2 2 3 Battery Pack for 3 kVA UPS 5 3 Installing the Battery Pack 7 3 1 Unpacking and Checking 7 3 2 Preparations 7 3 3 Installation Procedure 8 3 3 1 Rack Mounted Battery Pack 8 3 3 2 Tower mounting a Battery Pack 9 4 Connecting a Battery Pack and a UPS 12 4 1 Connecting a Battery Pack and a 1 kVA UPS 12 4 2 Connecting a Battery Pack and a...

Page 6: ...get the tool insulated and wear insulation gloves when connecting cables 6 To prevent personal injury wear protective shoes when moving the battery pack 7 In case of fire use a dry powder extinguisher to put out the fire Using a fluid fire extinguisher may cause electric shocks 8 Do not touch uninsulated battery terminals Otherwise electric shocks may occur 9 Using incorrect battery models may cau...

Page 7: ...e rack mounted or tower mounted As shown in Figure 2 1 and Figure 2 2 Figure 2 1 Rack mounted battery pack Figure 2 2 Tower mounted battery pack The standard battery pack for 1 kVA UPS is ESS 24V12 9 3AHBPVBB01 The standard battery pack for 2 kVA UPS is ESS 48V12 9 2AHBPVBB01 The standard battery pack for 3 kVA UPS is ESS 72V12 9AHBPVBB01 The appearance for 1 kVA UPS 2 kVA UPS and 3 kVA UPS are th...

Page 8: ... 2 DC port 2 3 Protection switch Table 2 1 describes the input and output ports on the battery pack Table 2 1 Input and output ports on the battery pack No Port Port Type 1 DC port 1 SA50 x 2 2 DC port 2 SA50 x 2 2 2 Features 2 2 1 Battery Pack for 1 kVA UPS Model ESS 24V12 9 3AHBPVBB01 Interior Three group of battery strings are embedded each group with two 9 Ah 12 V DC batteries The output volta...

Page 9: ...410 mm Weight 21 5 kg Graphics of the Interior Figure 2 4 ESS 24V12 9 3AHBPVBB01 battery pack interior 2 2 2 Battery Pack for 2 kVA UPS Model ESS 48V12 9 2AHBPVBB01 Interior Two group of battery strings are embedded each group with four 9 Ah 12 V DC batteries The output voltage of battery pack is 48 V DC Basic Features Color black Panel plastic Back plane grey SECC SGCC Dimensions H x W x D 88 mm ...

Page 10: ...cs of the Interior Figure 2 5 ESS 48V12 9 2AHBPVBB01 battery pack interior 2 2 3 Battery Pack for 3 kVA UPS Model ESS 72V12 9AHBPVBB01 Interior One group of battery string is embedded each group with six 9 Ah 12 V DC batteries The output voltage of battery pack is 72 V DC Basic Features Color black Panel plastic Back plane grey SECC SGCC Dimensions H x W x D 88 mm x 438 mm x 410 mm Weight 21 5 kg ...

Page 11: ... Quick Installation Guide 2016 Russia 2 Appearance and Feature Issue 02 2016 07 28 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 6 Graphics of the Interior Figure 2 6 ESS 72V12 9AHBPVBB01 battery pack interior ...

Page 12: ...ely Check that battery pack bar code on the rear of the pack near the wiring port is consistent with that specified in the order If any discrepancy is found contact local Huawei office immediately Do not transport the battery pack by holding the mounting ears front panel or protective cover Remove rings watches and other metal objects before you move the battery pack 3 2 Preparations Get installat...

Page 13: ...Technologies Co Ltd 8 Appearance Specifications and Name Wire stripper PVC insulation tape Cotton cloth Heat shrink tubing Heat gun Electrician s knife Protective gloves Electrostatic discharge ESD gloves Insulation gloves Hydraulic pliers Cable tie N A N A 3 3 Installation Procedure 3 3 1 Rack Mounted Battery Pack Procedure 1 Install mounting ears 2 Install the battery pack ...

Page 14: ...2016 07 28 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 9 The proposed torque is 3 N m here 3 3 2 Tower mounting a Battery Pack To tower mount a battery pack perform the following steps Procedure 1 Remove the front panel 2 Adjust the battery pack panel as shown in the following figure ...

Page 15: ...Pack Issue 02 2016 07 28 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 10 3 Adjust Huawei logo and reinstall the front panel 4 Assemble the support base and the extended part The support base is the accessory of UPS the accessory of battery pack only is the extended part ...

Page 16: ... Installing the Battery Pack Issue 02 2016 07 28 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 11 5 Install the battery pack The lateral dimensions of UPS and battery pack installed as the above figure is about 300 mm 6 The installation is complete ...

Page 17: ...2 2016 07 28 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 12 4 Connecting a Battery Pack and a UPS 4 1 Connecting a Battery Pack and a 1 kVA UPS Connect the ESS 24V12 9 3AHBPVBB01 battery packs and the 1 kVA UPS using the battery cable delivered with the battery pack as shown in Figure 4 1 ...

Page 18: ... used to connect the UPS or battery pack another can be used to connect an external charger In the preceding figures the unused port on the battery pack on the right can connect to an external charger Before connecting please make sure that the breaker of the battery pack is in the OFF state Figure 4 1 Connection between the ESS 24V12 9 3AHBPVBB01 battery pack and a 1 kVA UPS 4 2 Connecting a Batt...

Page 19: ... to connect the UPS or battery pack another can be used to connect an external charger In the preceding figures the unused port on the battery pack on the right can connect to an external charger Before connecting please make sure that the breaker of the battery pack is in the OFF state Figure 4 2 Connection between the ESS 48V12 9 2AHBPVBB01 battery pack and a 2 kVA UPS 4 3 Connecting a Battery P...

Page 20: ...e text uses two groups in parallel as an example If four groups need to be connected refer to the connection method of two groups The battery pack has two output ports as a parallel state the same function If one used to connect the UPS or battery pack another can be used to connect an external charger Before connecting please make sure that the breaker of the battery pack is in the OFF state Figu...

Page 21: ...S2000 G 1 kVA 3 kVA Battery Pack Quick Installation Guide 2016 Russia 4 Connecting a Battery Pack and a UPS Issue 02 2016 07 28 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 16 ...

Page 22: ... Pack Quick Installation Guide 2016 Russia AAcronyms and Abbreviations Issue 02 2016 07 28 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 17 A Acronyms and Abbreviations U UPS uninterruptible power system ...