3 Diagnostics
Tecal RH5485 Server
Problem Determination and Service Guide
3-102
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-05-25)
Message
Severity Description
Action
Security: Userid:%1 had %2
login failures from an SSH
client at IP address %3.
(
%1 = User ID
;
%2 = MaximumSuccessive
LoginFailures
(
currently set to 5
in the firmware
);
%3 =
IP address,
xxx
.
xxx
.
xxx
.
xxx
Error
A user has exceeded the
maximum number of
unsuccessful login attempts from
SSH and has been prevented
from logging in for the lockout
period.
1. Make sure that the correct
login ID and password are being
used.
2. Have the system
administrator reset the login ID
or password.
Sensor "TPM Phy Pres Set" has
transitioned from normal to
non-critical state
Info
The physical presence for
Trusted Platform Module (TPM)
has been detected.
No action; information only.
Table 3-21
Fan instances, sensor strings, and locations
Instance number
Sensor name
Location
1
Fan 1 Tach
Host server
2
Fan 2 Tach
Host server
3
Fan 3A Tach
Host server
3
Fan 3B Tach
Host server
4
Fan 4 Tach
Host server
5
Fan 5 Tach
Host server
6
MEU Fan 1 Tach
Memory expansion enclosure
7
MEU Fan 2 Tach
Memory expansion enclosure
8
MEU Fan 3 Tach
Memory expansion enclosure
9
MEU Fan 4 Tach
Memory expansion enclosure
10
MEU Fan 5 Tach
Memory expansion enclosure
3.12 Solving Ethernet controller problems
The method that you use to test the Ethernet controller depends on which operating system
and which switch you are using. See the operating-system and switch documentation for
information about Ethernet controllers, and see the Ethernet controller device-driver readme
file.
Try the following procedures:
Make sure that the correct device drivers, which come with the server, are installed and
that they are at the latest level.
Make sure that the Ethernet cable is installed correctly.
−
The cable must be securely attached at all connections. If the cable is attached but the
problem remains, try a different cable.