SmartLogger1000
User Manual
7 WebUI
Issue 12 (2019-01-15)
Copyright © Huawei Technologies Co., Ltd.
221
Figure 7-45
Setting Ethernet parameters
If the SmartLogger connects to the Internet through a router, note the following when setting
Ethernet parameters:
Set the gateway address to the IP address of the router.
Ensure that the IP address of the SmartLogger is in the same network segment as the
gateway address.
Set the domain name server (DNS) address to the IP address of the router or obtain the
DNS address from the network provider.
If the IP address is changed, you need to use the new IP address to log in to the system.
7.10.2.2 Setting RS485 Parameters
Because of permission restriction, log in as
Advanced User
or
Special User
. Choose
Settings
>
RS485
to access the target page.
Figure 7-46
RS485 parameters