Example
To set the password for registering with the OLT through the GPON port, set the lower limit for
the receive optical power of the optical transceiver to 5 dBm and the upper limit for the receive
optical power of the optical transceiver to 50 dBm, set the working mode of the optical
transceiver of the upstream PON port to
auto
, do as follows:
huawei(config-if-gponnni-0/0/1)#
password
{ passwordvalue<S><Length 1-10> }:
huawei
Command:
password huawei
huawei(config-if-gponnni-0/0/1)#
optical-module threshold rx-power lower-limit 5
upper-limit 50
{ <cr>|bias<K>|temperature<K>|tx-power<K>|voltage<K> }:
Command:
optical-module threshold rx-power lower-limit 5 upper-limit 50
huawei(config-if-gponnni-0/0/1)#
laser auto
3.3.3 Configuring the System Energy-Saving Function
This topic describes how to power off an unnecessary board to reduce power consumption and
save system energy.
Prerequisites
The board supports power-off and energy-saving modes.
Context
The MA5616 supports manual energy-saving mode. Manual energy-saving allows you to power
off a board manually. Specifically, you can manually power off a board that is not used according
to data plan to reduce energy consumption. When you are about to provision a service on a board
that is manually powered off, the system displays a message indicating that the board is powered
off. In this case, power on the board manually. By default, the energy-saving mode is disabled.
Procedure
l
Run the
board power-off
command to manually power off a board.
–
When a board is not configured with any service, manually power off the board to reduce
energy consumption.
–
After a board is power off manually, run the
board power-on
command to power on
the board.
CAUTION
Exercise caution when running this command because this command will interrupt services
on a board.
l
Run the
broad-service power-off shutdown
command to disable bandwidth services.
–
When an AC-powered device is powered off and is powered by a battery, disable
bandwidth services so that narrowband services can be used for a long time.