APPENDIX:
-------------------------------------------------
Interface software parameter name:
6: Whether MG supports authentication
0: Yes
1: No
huawei(config-if-h248-0)#
auth auth_mgid MA5616 initial_key 0123456789ABCDEF
huawei(config-if-h248-0)#
display auth
[AUTH_PARA config]
Initial Key : 0123456789ABCDEF
Auth MGid : MA5616
Algorithm : MD5
huawei(config-if-h248-0)#
reset coldstart
Are you sure to reset MG interface?(y/n)[n]:
y
7.8.1.2 Configuring the Device Authentication (Based on the SIP Protocol)
This topic describes how to configure the authentication information for the SIP interface or a
single user of the MA5616 when the SIP protocol is used.
Prerequisites
l
The SIP interface must be added successfully on the MA5616.
l
The authentication user name and password must be configured on the IMS. Such
parameters must be the same as the authentication user name and password configured on
the MA5616.
Context
l
The authentication information can be configured for the SIP interface. The configuration
takes effect only after you run the
reset
command on the SIP interface.
l
The authentication information can be configured for a single user. The configuration takes
effect immediately after the configuration is complete.
l
In the actual application, whether the user uses the authentication information configured
for the SIP interface or a single user can be controlled through system parameter 81 in the
sipprofile modify
command.
Procedure
l
Configure the authentication information for the SIP interface.
1.
In the global config mode, run the
interface sip
command to enter the SIP interface
mode.
2.
Run the
sip-auth-parameter
command to configure the authentication user name and
password for an SIP interface.
3.
Run the
display sip-auth
command to query the authentication information of an SIP
interface.
4.
Run the
reset
command to reset the SIP interface.
l
Configure the authentication information for a single user.
1.
Run the
esl user
command to enter the ESL user mode.
2.
Run the
sippstnuser auth set
command to configure the authentication user name
and password for a single user.
SmartAX MA5616 Multi-service Access Module
Configuration Guide
7 Configuring the Voice Service
Issue 04 (2011-10-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
308