Step 4
Check whether the configuration of the digitmap timer is the same as that in the data plan.
l
Run the
display digitmap
command to check whether the digitmap is configured correctly.
l
Run the
display digitmap-timer
command to check whether the digitmap timer is configured
correctly.
----End
Example
Assume that the inner digitmap of the H.248-based MG interface is configured. According to
the data plan, the inner digitmap format is 1234xxxx. The digitmap timer is not configured
because it is issued by the MGC. To configure the inner digitmap, do as follows:
huawei(config)#
interface h248 0
huawei(config-if-h248-0)#
digitmap set inner 1234xxxx
huawei(config-if-h248-0)#
display digitmap
----------------------------------------------------------------------
Inner digitmap : 1234xxxx
Urgent digitmap (for overload or bandwidth restrict) : -
Dualdial digitmap for card service : -
----------------------------------------------------------------------
7.3.1.5 (Optional) Configuring the Software Parameters of an MG Interface
The software parameters of an MG interface mainly define certain common service attributes
of the MG interface. After the configuration of the software parameters of an MG interface, the
software parameters take effect immediately and the configuration is valid only to the MG
interface.
Context
There are 36 software parameters (numbered from 0 to 35) of an MG interface that supports H.
248.
lists the configurable parameters, and the other parameters are reserved in the
system.
SmartAX MA5616 Multi-service Access Module
Configuration Guide
7 Configuring the Voice Service
Issue 04 (2011-10-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
276