Step 8
Save the data.
huawei(config)#
save
----End
12.3.7 Configuring the SIP-based Voice Service (on a Web Page)
The OLT is connected to the remote ONU through a GPON port to provide users with the IP-
based high-quality and low-cost VoIP service.
Prerequisite
l
The SIP interface data and POTS port data corresponding to the MG interface have been
configured on the SIP server.
l
The connection between the OLT and the SIP server is set up. The OLT can ping the IP
address of the SIP server successfully.
l
The ONU has been added to the OLT. For details, see
l
Different voice services require different ONU software versions. Before the configuration,
ensure that the current ONU software version supports SIP. For details, see relevant ONU
manuals.
Data Plan
Table 12-10
Data plan
Item
Data
ONU line profile
Profile name: ftto_line
T-CONT ID: 4
GEM port ID: 12
ONU service profile
Profile name: ftto_ser
ONU port capability set: adaptive
Voice parameter
IP address of the SIP server: 200.200.200.200/24
Port ID of the SIP server: 5060
Home domain name: huawei.com
User phone number 1: 77730010
User phone number 2: 77730020
Procedure
l
Configure the OLT.
1.
Configure a traffic profile.
Set the profile name to
ftto_voip
and do not limit the upstream and downstream rates.
Set the priority to
5
and packets are scheduled according to the priority carried.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
12 FTTO Configuration(SOHO and SME)
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1119