background image

Summary of Contents for S5700-28P-LIAC

Page 1: ...S5700 LI Series Gigabit Enterprise Switches ...

Page 2: ......

Page 3: ...tteries can provide power redundancy at lower costs but have low reliability and security short lifespan and also occupy significant space Huawei battery LAN switches solve this problem The use of internal batteries ensures stable operation of the access layer in the event of power failures CSFP switches support downlink CSFP ports and each downlink CSFP port provides 2 Gbit s bandwidth bidirection...

Page 4: ...ernet ports 4 10GE SFP ports 10GE GE auto sensing Ac power supply supporting RPS redundant power supply PoE Forwarding performance 96 Mpps S5700 28X LI 24S AC 24 GE SFP ports four Combo 10 100 1000Base T Ethernet ports four 10GE SFP ports 10GE GE auto sensing Two models AC model and DC model supporting RPS redundant power supply Forwarding performance 96 Mpps S5700 28X LI 24S DC S5700 28X LI AC 24...

Page 5: ...wer module used as the redundant power source Forwarding performance 42 Mpps 24 10 100 1000Base T Ethernet ports 4 GE SFP ports AC power supply One battery slot for a pluggable 4AH lithium battery 8AH lithium battery or external lead acid battery used in the event of a mains power failure or a 150 W AC or DC power module used as the redundant power source Forwarding performance 42 Mpps 28 GE SFP p...

Page 6: ...ng network topologies such as open ring topology closed ring topology and cascading ring topology This protocol is reliable easy to maintain and implements fast protection switching within 50 ms ERPS is defined in ITU T G 8032 It implements millisecond level protection switching based on traditional Ethernet MAC and bridging functions The S5700 LI supports Smartlink which implements backup of uplin...

Page 7: ...plement dynamic distribution registration and propagation of VLAN attributes GVRP reduces manual configuration workload and ensures correct configuration Additionally the S5700 LI supports MUX VLAN which involves a principal VLAN and multiple subordinate VLANs Subordinate VLANs are classified into group VLANs and separate VLANs Ports in the principal VLAN can communicate with ports in subordinate VLA...

Page 8: ...hes using external power supply units the S5700 LI BAT occupies less space and is easier to install Intelligent power management long standby time Battery LAN switches on the entire network can be managed centrally using a web system facilitating network operation and maintenance As the battery lifetime is predictable you do not need to replace batteries periodically reducing hardware costs The in...

Page 9: ...MSTP IEEE 802 1s BPDU protection root protection and loop protection IP routing Static route IPv6 features Neighbor Discovery ND Path MTU PMTU IPv6 ping IPv6 tracert and IPv6 Telnet ACLs based on the source IPv6 address destination IPv6 address Layer 4 ports and protocol type MLDv1 v2 snooping Multicast IGMPv1 v2 v3 snooping and IGMP fast leave Multicast forwarding in a VLAN and multicast replicat...

Page 10: ...otocol Secure HTTPS CPU defense Blacklist and whitelist Surge protection Service interface 6 kV Management and maintenance iStack excluding S5700 10P LI AC S5700 10P PWR LI AC and battery LAN switches MFF Virtual Cable Test VCT Remote configuration and maintenance using Telnet SNMPv1 v2 v3 RMON eSight and web based NMS HTTPS System logs and multi level alarms GVRP MUX VLAN 802 3az EEE Dying Gasp ex...

Page 11: ...s Note Battery type Internal BAT 4AHA and BAT 8AHA lithium batteries and external lead acid batteries connected to the lead acid battery charger module in the battery slot supported by battery LAN switches Battery management Web based management system used to check the battery status and manage the battery supported by battery LAN switches Dimensions width x depth x height mm S5700 10P LI AC 250 ...

Page 12: ... recovers the switch automatically charges the lithium battery The use of internal batteries ensures high reliability at the access layer in the case of frequent mains power failures Applications S9700 S7700 S7700 S5700 LI Campus Core layer Campus equipment room Centralized deployment UPS for power redundancy S5700 LI BAT Internal lithium battery Office building Aggregation later Access layer S970...

Page 13: ...C 48 10 100 1000Base T Ethernet ports 4 GE SFP ports PoE AC power supply S5700 52X PWR LI AC 48 10 100 1000Base T Ethernet ports 4 10GE SFP ports PoE AC power supply S5700 28X LI 24S AC 24 GE SFP ports 4 Combo 10 100 1000Base T Ethernet ports 4 10GE SFP ports AC power supply S5700 28X LI 24S DC 24 GE SFP ports 4 Combo 10 100 1000Base T Ethernet ports 4 10GE SFP ports DC power supply S5700 28P LI B...

Page 14: ...ead acid battery charger module CBTS3400 temperature sensor used for temperature compensation when the lead acid battery is charged 150 W AC power module optional for battery LAN switches used as the redundancy for the internal power module 150 W DC power module optional for battery LAN switches used as the redundancy for the internal power module For more information visit http enterprise huawei ...

Page 15: ...13 ...

Page 16: ...ments regarding the future financial and operating results future product portfolio new technology etc There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements Therefore such information is provided for reference purpose only and constitutes neither an offer nor an acceptance Huawei may change t...

Reviews: