No.
Data
1
ID of the Monitor Link group
2
Number of each interface added to the Monitor Link group
3
Revertive switching interval of the Monitor Link group
4
ID of the Smart Link group
2.4.2 Creating a Monitor Link Group
Context
Do as follows on SwitchA and SwitchB.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
monitor-link group
group-id
A Monitor Link group is created and the Monitor Link group view is displayed.
----End
2.4.3 Configuring the Uplink and Downlink Interfaces in a Monitor
Link Group
Context
Do as follows on SwitchA and SwitchB.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
monitor-link group
group-id
The Monitor Link group view is displayed. The S3700 supports a maximum of 16 Monitor Link
groups.
Step 3
Run:
port
interface-type
interface-number
{
downlink
[
downlink-id
] |
uplink
}
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
2 Smart Link and Monitor Link Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
30