The Smart Link group view is displayed.
Step 3
Run:
smart-link force
Data flows are locked on the slave interface.
----End
2.3.4 Switching Data Flows Manually
Context
Do as follows on SwitchD shown in
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
smart-link group
group-id
The Smart Link group view is displayed.
Step 3
Run:
smart-link manual switch
Data flows are switched to the other link.
To implement active/standby switchover between links, ensure that:
l
The master interface and slave interface exist and are both in Up state.
l
The
smart-link
command is not run to lock data streams.
The
smart-link manual switch
command can be repeatedly used in the Smart Link group view.
Each time you run the command, the active/standby switchover is performed between links.
Packet loss occurs during the switchover. The duration is measured in milliseconds.
----End
2.3.5 Checking the Configuration
Procedure
Step 1
Run the
display smart-link group
{
all
|
group-id
} command to check information about a
Smart Link group.
----End
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
2 Smart Link and Monitor Link Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
27